DAIRY EQUIPMENT Dari-Kool Gebrauchsanweisung - Seite 12

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Gefrierschrank DAIRY EQUIPMENT Dari-Kool herunter. DAIRY EQUIPMENT Dari-Kool 14 Seiten. Bulk milk cooler

5. When removing or placing the plug in the valve body,
extreme care should be taken to prevent the plug from
hitting the edge of the valve body and causing a nick.
Such a nick, if not removed, will score the inside of
the body causing the valve to leak.
6. After washing, valve plugs should always be inspected
before being placed in the valve body.
If a nick is
present it should be removed with a fine file.
7. Valve bodies and valve plugs are matched during manu­
facture.
Plugs and bodies are not interchangeable.
8. Never open or close a valve without first loosening
the bottom nut and never open a valve by hammering
it as this will ruin it.
9. Never tighten the bottom nut too tightly.
Hand
tightening is sufficient.
Excess tightening will not
cause a valve to stop leaking.
If a valve is leaking,
look for the cause and remedy it.
10. Do not attempt Lo grind or relap a valve.
This can
only be done at the factory where proper facilities
are available.
11. If the valve leaks due to damage or nicks, it cannot
be considered "in warranty" and charges must be made
for repair.
DAIRY EQUIPMENT COMPANY
A DIVISION OF DEC INTERNATIONAL, INC.
MADIISO'N, WISCONSIN
-10 ­