Ansell 406143516 Einbauanleitung
Blättern Sie online oder laden Sie pdf Einbauanleitung für Beleuchtungsanlagen Ansell 406143516 herunter. Ansell 406143516 2 Seiten. Falcon 6500k led surface emergency downlight - self test – ip65
General Installation Instructions
These instructions should be read carefully prior to any installation and retained after completion for further
reference and maintenance. Please give these instructions to the building owner/occupier after installation.
Important Safety
1.
Before installation, maintenance or lamp replacement, ensure that the mains supply to the luminaire is switched off and the circuit supply fuses are removed or
the circuit breaker is turned off.
2.
It is recommended that only a qualified electrical contractor carries out the installation of this luminaire and that the luminaire is installed in compliance with the
current edition of the IEE Wiring Regulations.
3.
The person carrying out the installation is to check and verify that the total load on the circuit, including that of this luminaire does not exceed the rating of the
circuit cable, fuse or circuit breaker.
4.
Where a luminaire incorporates discharge control gear (inductive load), the circuit capacity and ratings require careful sizing to avoid nuisance tripping of the
protective device used in the installation.
5.
Where applicable, careful consideration should be taken during installation to ensure that all fixings and/or suspensions are of a suitable size for the luminaire
being installed.
Ratings
1. All luminaires are manufactured & tested in compliance with the requirement contained within BS EN 60598 and are CE marked.
2. All luminaires that are of Class 1 construction and that are marked accordingly, MUST be earthed.
3. All luminaires are designed to operate at 230Volts AC -6%/+10% = 216Volts to 252Volts. Do not operate outside these voltages.
4. All luminaires are only suitable for applications within their rated Ingress Protection limits as stated
Exclusions to Warranty
Please Note - The limited warranty shall be null and void in the following circumstances:-
Failure by the installer, end user or any third party to exercise caution to protect any covered product or part from outside damage, adverse temperature (normal
operating ambient temperature 0 - 25°C), humidity conditions, fluctuations in the electrical system or physical abuse as well as failure related to workmanship in the
installation of the products or parts.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
INSTALLATION
•
Select a suitable mounting surface and provide a suitable power supply.
•
Remove the luminaire cover/diffuser by depressing the retaining clips, 3 of which are situated around the downlight.
•
For ease of installation, the LED cover can be removed by disconnecting the two plugs to the PCB. If removed store in a safe area.
•
Fix the base to the required surface ensuring an appropriate fixing method is used to support the luminaire.
•
Bring in the incoming supply through the base and terminate into the terminal block on the gear tray.
Electrical Connection
Connect as follows:-
PERMANENT LIVE
EARTH
NEUTRAL
•
Connect the battery plug to the PCB board where indicated.
•
Connect the LED cover if removed and fit the cover into position.
•
There are two types of lens supplied, Open Area(OA) and Escape Route(ER),If installing the Escape Route lens be sure to fix the base in
the correct orientation so the output of the LED provides the escape route emergency output pathway required.
•
Please see below image explaining how to remove/replace the lens. Fig.1
•
Switch on the mains supply. Check the unit operates correctly.
•
Check the LED indicator is GREEN and ON.
Fig.1
Note
•
The unit requires 48 hours to fully charge the battery and achieve 3 hours emergency operation.
•
DO NOT deep discharge the batteries pack in emergency output for over a period of 48hrs as this will cause irreparable damage
to the battery.
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Page 1.
Ansell Electrical Products, Unit 6B, Stonecross Ind. Park, Yew Tree way, Warrington, WA3 3JD
Description – Falcon 6500K LED Surface Emergency
Installation Instructions
®
Luminaire Code(s )–
(L)
BLACK (continuous)
GREEN / YELLOW
(N)
BLUE
Downlight - Self Test – IP65
AFALED/3NM/ST/IP65
Issue 1.0
www.anselluk.com