HOOK-UP DIAGRAM

120VAC
60Hz
TRANSFORMER
16VAC 20VA MIN.
DO NOT CONNECT TRANSFORMER
TO SWITCHED RECEPTACLE.
RECOMMENDED TRANSFORMER:
BASLER ELECTRIC BE 116240CAA-0002
RED
+
BATTERY CAPACITY FOR
EMERGENCY STAND-BY
BATTERY
IS AT LEAST 4 HOURS
IF THE TOTAL LOAD
12V GELL CELL
(BELL & AUX OUTPUTS)
IS 800mA OR LESS AND
THE BATTERY HAS
4 Ah CAPACITY.
BATTERY CHARGE
CURRENT IS 360mA MAX.
RECOMMENDED BATTERY:
YUASA NP4-12.
Z1 COM Z2
NC
EOL RESISTOR
LOOPS USING
NO
NO & NC
DEVICES
END OF LINE
END OF LINE
RESISTOR
5600Ω 0.5W
5600Ω 0.5W
Recognized limited energy cable should be used. Observe local codes as defined by the authority having jurisdication.
Refer to Installation and Instruction Manuals for complete operating instructions.
Detection devices that require power from the Control Panel should operate over the range of 10.0 to 14.0 VDC.
The DSC BRAVO models are recommended motion detectors. The DSC DG-50 is a recommended glassbreak detector.
Temperature Range: 0˚C to 49˚C (32˚F to 120˚F). Maximum Humidity: 85% relative humidity
INCORRECT CONNECTIONS MAY RESULT IN
FUSE FAILURE OR IMPROPER OPERATION.
INSPECT WIRING AND ENSURE CONNECTIONS
ARE CORRECT BEFORE APPLYING POWER.
DO NOT REPLACE FUSES
WITH HIGHER VALUES
THAN SHOWN
BLK
OBSERVE POLARITY!
NC
EOL RESISTOR
NC
LOOPS USING
NC DEVICES
ONLY
RESISTOR
firealarmresources.com
PROGRAMMABLE
PROGRAMMABLE
BELL/SIREN
1A MAX.
GRN
YEL
BLK
RED
PC500RK KEYPAD
3 MAXIMUM PER SYSTEM
KEY
COM
MOMENTARY OR
MAINTAINED CONTACT
KEYSWITCH
CONFIGURATION IN SECTION [05].
IF KEY TERMINAL IS TO BE USED
END OF LINE
AS A TAMPER ZONE, CONNECT THE
RESISTOR
ZONE AS SHOWN IN THE "TYPICAL
5600Ω 0.5W
BURGLARY ZONE CONNECTIONS"
REFER TO
ZONE CONNECTIONS
BELOW
OUTPUT 2
LOAD
TO AUX+
50mA MAX.
LOAD
TO AUX+
50mA MAX.
OUTPUT 1
Ready
Armed
System
Zone 1
OR
Zone 2
Zone 3
Zone 4
SL-40 KEYPAD
PROGRAM KEY TERMINAL
DIAGRAM.
15