5. Installation precautions
IMPORTANT: make sure each product is at least two metres away from other devices, except
other detectors.
The detector must be placed: perpendicular
to entrance points to be protected to ensure
intruders are quickly detected.
Right
Wrong
The detector must not be placed:
• facing a moving object (branches, bushes,
curtains, etc.),
• do not place where the detection beams
are likely to be directly or indirectly
impacted by the sun's rays or by a very
powerful source of light,
• skew in relation to the wall,
• do not fix directly on a metal wall or close
to sources of interference (e.g. heat pump).
77
6. Installing the detector
Before fixing the detector in place:
1. Define the fixing height (2.5 to 3 m).
2. Determine the detection zone.
3. With the detector in the chosen location,
check the radio link with the control panel:
Press (> 5 s) on the detector "test" button.
The control panel will issue the voice
message: "beep, test detector X
(personalised message), group Y,
immediate (or delayed or combinated)".
"beep, test detector X, group Y,
(immediate or delayed
or combined)"
)
)
)
)
)