DAITEM SH602AX Installationshandbuch - Seite 4

Blättern Sie online oder laden Sie pdf Installationshandbuch für Sicherheitssystem DAITEM SH602AX herunter. DAITEM SH602AX 8 Seiten. 2 function remote keyfob with information feedback, bi-protocol 4 function remote keyfob with information feedback,8 function 4 key remote keyfob with information feedback

4. Set the parameters according to the sequence below.
R
R
LED off
about 10 s
press as
shown
To begin,
Press briefly
simultaneously
on the key
press the
and
to be
keys until the LED
personalised:
goes out
,
or
IMPORTANT
• Each command n° digit corresponds to the number of times the keyfob is pressed (digit "0" = key pressed 10 times in a row)
• If the red LED flashes three times in a row during or at the end of parameter-setting, you have made a programming error.
When this happens, go through the sequence again from the beginning.
Example of parameter-setting
Personalise key P1 to trigger a "Silent alarm". The command n° is 24.
R
R
R
Start
Select key
to create
a space
Verification of parameter setting of the preceding example
R
R
R
Start
Select key
to create
a space

4.2 Setting a key to Arm or Disarm groups 1 to 8

The arming or disarming of a group from among the 8 alarm groups available (depending on the type of control panel) can be
programmed by first configuring:
• the Disarm group function (command 121) and associating this with the group(s) to be disarmed,
• the Arm group function (command 123) and associating this with the group(s) to be disarmed.
IMPORTANT: a key cannot be set with a TwinBand
Optwin
®
radio link is deleted).
Example of parameter-setting
Personalising the P1 key to trigger the "Off group" function (command 121) associated with groups 1 and 8.
R
R
R
To begin,
Press briefly
Press and
simulta -
to select
hold a key
neously
the
key
until the
press the
LED goes
and
keys
out and
until the LED
release the
goes out
key when
the LED
lights up
a 2
R
R
R
R
about 5 s
Press and hold
Press the key
as many times
the key until
as the 1
the LED goes out
and release
command n°
,
the key when
the LED lights up
a 2
nd
time.
R
R
R R
2
Press
Press twice
for the 1
digit
st
R
R
R
R
Press
End
The LED flashes
twice to confirm
the 1
command n° if an Optwin
®
R
R
R
R R
1
2
Press
Press
once
twice
for the
for the
1
st
digit
2
nd
digit
"Off Group"
command parameter-setting
nd
time
R
R
R
R
about
about
2 s pause
2 s pause
Press the key
Press the key
as many times
as many times
st
digit
as the 2
nd
digit
as the 3
of the
of the
of the
command n°
command n°
R R R R
R
R
4
Press 4 times
End
for the 2
digit
nd
R R
R R R R
2
4
The LED flashes
4 times to confirm
st
digit
the 2
nd
digit
radio link has already been allocated (unless the
®
R
R
R
R
1
1
Press
Press and
Press
once
once
hold a key
for the
for group 1
until the LED
3
rd
digit
goes out and
release the
Groups 1 and 8
key when the
associated
LED lights up
a 2
nd
time.
4
R
R
R
about 10 s
about
To end the
Steady green
sequence press
LED =
rd
digit
and hold the key
parameters
until the LED goes
correctly set.
out.
Steady green LED =
parameters correctly set
The green LED lights up
for 1.5 s at the end
of consultation
R
R
R
R
8
Press
To end the
eight
sequence
times
press and
for group 8
hold a key
until the LED
goes out
1.5 s
R
red LED
green LED
R
red LED
green LED
R
red LED
green LED
Steady green
LED =
parameters
correctly set