DSC PowerSeries PC1616 Installationshandbuch - Seite 14

Blättern Sie online oder laden Sie pdf Installationshandbuch für Sicherheitssystem DSC PowerSeries PC1616 herunter. DSC PowerSeries PC1616 20 Seiten. System enhancement module
Auch für DSC PowerSeries PC1616: Installationshandbuch (17 seiten), Installationshandbuch (13 seiten), Kurzanleitung (4 seiten), Handbuch (18 seiten)

DSC PowerSeries PC1616 Installationshandbuch
4
The Alarm.com module is registered on the cellular network
but could not connect with Alarm.com. Contact Alarm.com
Technical Support.
5
The radio on the module is not working correctly. If this persists
for more than a few minutes the module may need to be
replaced. This error is extremely rare, so please verify that the
module is flashing 5 times.
6
This indicates an error only if it persists for more than a
minute. Otherwise, it's an indication that the module is
resolving an unusual condition regarding communication
with the cellular network.
7
The SEM is unable to access panel programming.
Check panel wiring and Installer Code.
8
If this error persists, the account may have been set up
incorrectly. Check that the serial number being used matches
the serial number used to create the account. If the serial
numbers are the same, contact Technical Support.
LED L2 (YELLOW)
L2 flashes with every communication between the SEM and the panel.
The normal pattern calls for a series of quick flashes every two seconds
when the Alarm.com module is in Idle mode or four seconds in PowerSave
mode. See Alarm.com Module States (modes) for an explanation of the
three modes.
L2 also occasionally flashes in patterns to indicate Z-Wave status,
when the SEM is being used to add or remove Z-Wave devices.
LED L3 (GREEN OR YELLOW)
L3 flashes with every communication between the SEM and its radio unit
in Idle mode, and with every communication with Alarm.com in Connected
mode. In PowerSave mode, this LED flashes in unison with LED L2.
LED L4 (GREEN OR YELLOW)
L4 indicates the cellular signal level as a number of flashes (0 to 5 bars).
The number of bars may not correspond to the number of bars shown
on your cell phone. A level of 5 bars is obtained only in the strongest
signal conditions. Signal level is updated every ten seconds if it fluctuates,
or every 30 seconds if it is fairly stable.
If LED L4 is continuously flashing, the module provisioning process is
in progress. LED L4 will begin flashing to indicate signal level as soon
as the provisioning process is complete.
If LED L4 is not flashing, this means one of the following:
The Alarm.com module is in PowerSave mode
The Alarm.com module just powered up
There is no cellular coverage in the area
In Connected mode, LED L4 toggles on and off.
TIP:
Alarm.com recommends a steady signal level of two
or higher for proper operation of the SEM.
14