DSC PowerSeries PC1864 Installationshandbuch - Seite 17
Blättern Sie online oder laden Sie pdf Installationshandbuch für Sicherheitssystem DSC PowerSeries PC1864 herunter. DSC PowerSeries PC1864 20 Seiten. System
enhancement
module
Auch für DSC PowerSeries PC1864: Installationshandbuch (17 seiten), Installationshandbuch (13 seiten), Handbuch (18 seiten)
Is the SEM compatible with DLS?
The SEM cannot be used as a DLS communicator. DLS panel programming
changes via another communication pathway (PC Link, POTS, etc.) will not
be captured by the SEM until the system is power cycled.
Do I need to change any programming settings for the SEM to work?
No, there aren't any required settings that need to be changed.
However, we do recommend changing the following settings if the
system was previously communicating over the phone line.
•
Disable Telco Line Monitoring (section 15, option 7)
•
Remove the phone numbers (section 301-303)
Does the SEM support reporting multiple alarms on a single zone
(swinger shutdown)?
The SEM will only report one instance of each alarm per alarm event
regardless of the settings specified on the panel. The SEM does not
support reporting multiple alarms on a single zone.
Can I can add and delete sensors remotely?
Yes, sensors can be added, changed, or deleted using MobileTech
or AirFX on the Dealer Website.
TROUBLESHOOTING
The Equipment List is empty on the Dealer Website or MobileTech
If the Equipment List is not showing on the Dealer Website or MobileTech
and the SEM failed to do a zone scan when initially powered on, verify that:
•
All wiring is correct
•
The Installer Code is synced (if the Installer Code is out of
sync you can change it to a new, unique code locally at the panel)
•
The panel is disarmed, and Request an Equipment List on the
Dealer Website or power cycle the panel
None of the LEDs on the SEM are ON
Remove power from the panel and verify that all wiring is correct.
My keypad will occasionally display "System Unavailable"
The keypad may display "System Unavailable" for brief moments while
interacting with the SEM. This is normal and expected behavior.
17