DSC PG9933 Installations- und Betriebsanleitung für den Installateur

Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für den Installateur für Sicherheitssensoren DSC PG9933 herunter. DSC PG9933 9 Seiten. 915mhz wireless carbon monoxide detector

DSC PG9933 Installations- und Betriebsanleitung für den Installateur
PG9933 (915MHz) Wireless Carbon Monoxide Detector
Installation and Operating Instructions
Read these instructions thoroughly before installation and use of the PG9933
The PG9933 is designed to monitor the CO gas level in residential dwellings and give
early warning before dangerous levels are detected. This device is intended to be used
with a compatible wireless alarm system. The detector consists of an electrochemical
carbon monoxide sensor assembly coupled to a wireless transmitter.
The Wireless Carbon Monoxide Alarm communicates with the control panel and can
send alarm, tamper and battery condition messages to the system receiver.
CAUTION: The detector expiry date is stamped on the detector. After the
expiry date, the detector should not be used - do not wait for end- of-life indic-
ation!
CAUTION: Unauthorized removal of the unit from the mounting bracket will
initiate a tamper alert.
Warnings:
The PG9933 wireless Carbon Monoxide detector shall be installed and used within an
environment that provides the pollution degree max 2 and overvoltages category II in
NON HAZARDOUS LOCATIONS, indoor only. The equipment is designed to be
installed by SERVICE PERSONS only; (SERVICE PERSON is defined as a person
having the appropriate technical training and experience necessary to be aware of haz-
ards to which that person may be exposed in performing a task and of measures to min-
imize the risks to that person or other persons.)
Failure to properly install, test and maintain a CO detector may cause it to fail, res-
ulting in loss of life. Installation of the CO detector should not be used as a substitute
for proper installation, use and maintenance of fuel burning appliances, including
appropriate ventilation and exhaust systems.
This carbon monoxide detector is designed for indoor use only. Do not expose it to
rain or moisture. Do not knock or drop the detector. Do not open or tamper with the
detector as this could cause malfunction. The detector will not protect against the risk
of carbon monoxide poisoning if not properly installed.
CAUTION: This device will only indicate the presence of carbon monoxide gas at the
sensor. Carbon monoxide gas may be present in other areas. This carbon monoxide
alarming device is designed to detect carbon monoxide gas from ANY source of
combustion. It is NOT designed to detect smoke, fire or other gases unless the product
has been investigated and determined to comply with applicable requirements.
WARNING! To comply with FCC and IC RF exposure compliance requirements, the
device should be located at a distance of at least 20 cm from all persons during normal
operation. The antennas used for this product must not be co- located or operated in
conjunction with any other antenna or transmitter.
Figure 1: Wireless CO Detector
B
A
Legend
A. Alarm LED (see Table 1 for LED indications)
B. Tamper release opening
C. Test/Hush button
D. Battery compartment
E. Breakaway tab (see Figure 3)
C
D