DSC WLS912 Handbücher und Installationsanweisungen

Blättern Sie online oder laden Sie pdf Handbücher und Installationsanweisungen für Sicherheitssensoren DSC WLS912 herunter. DSC WLS912 2 Seiten. Glassbreak detector
Auch für DSC WLS912: Einbauanleitung (2 seiten)

DSC WLS912 Handbücher und Installationsanweisungen
FCC Compliance Statement
CAUTION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void your authority
to use this equipment.
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the
manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to com-
ply with the limits for Class B device in accordance with the specifications in Subpart "B" of Part 15 of FCC Rules, which are
designed to provide reasonable protection against such interference in any residential installation. However, there is no guar-
antee that interference will not occur in a particular installation. If this equipment does cause interference to television or radio
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Re-orient the receiving antenna
• Relocate the alarm control with respect to the receiver
• Move the alarm control away from the receiver
• Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The
user may find the following booklet prepared by the FCC helpful: "How to Identify and Resolve Radio/Television Interfer-
ence Problems". This booklet is available from the U.S. Government Printing Office, Washington, D.C. 20402, Stock # 004-
000-00345-4.
Limited Warranty
Digital Security Controls Ltd. warrants that for a period of twelve months from the date of purchase, the product shall be free
of defects in material and workmanship under normal use and that in fulfilment of any breach of such warranty, Digital Secu-
rity Controls Ltd. shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot.
This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling, or damage
due to causes beyond control of Digital Security Controls Ltd. such as lightning, excessive voltage, mechanical shock, water
damage, or damage arising out of abuse, alteration or improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties,
whether express or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd. This warranty
contains the entire warranty. Digital Security Controls Ltd. neither assumes responsibility for, nor authorizes any other person
purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability con-
cerning this product.
In no event shall Digital Security Controls Ltd. be liable for any direct, indirect or consequential damages, loss of anticipated
profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation or fail-
ure of this product.
©2001 Digital Security Controls Ltd.
Toronto, Canada
1-800-387-3630 • www.dsc.com
Printed in Canada 29003922 R003
WLS912
Available Models: WLS912 and WLS912-433
Glassbreak Detector
I N S T A L L A T I O N
I N S T R U C T I O N S
The WLS912 is a battery-operated glassbreak sensor. It is designed to detect the sound pro-
duced by the shattering of framed glass. Equipped with an RF transmitter, the WLS912 estab-
lishes a supervised, one–way communications link with the system controller.
The WLS912 uses Dynamic Signal Processing* to provide accurate detection of the breaking
of framed plate, laminated, wired and tempered glass types, while rejecting common false
alarm sounds.
*Protected under US Patent 5,675,320
Specifications
Operating Voltage........................4.5V (three "AA" Alkaline Batteries)
o
Operating Temperature ................0
C - 50
Operating Humidity......................5% – 95% RH, non-condensing
Maximum Detection Range
Glass Type
Thickness
Minimum Glass
Size (L X W)
Plate (Float)/
1/8" – 1/4"
12" X 12"
Tempered
3 – 6mm
30cm X 30cm
Wired/
1/4"
18"X18"
Laminated
6mm
46cmX46cm
Place the detector a minimum of 1m (3.3ft) from the glass to ensure proper sound detection.
Battery Guidelines and Installation
Before installing batteries, please note the following guidelines:
The detector is designed to work with Eveready Alkaline Energizer "AA" batteries.
Do not install any other type. "No-name" or generic brand batteries may not
provide the best quality and dependability.
Always replace all three batteries at the same time.
When disposing of used batteries, follow the instructions and precautions printed
on the batteries. Many cities and communities have collection sites or services for
used household batteries. Contact your municipal offices for information on the
disposal of used batteries.
To install batteries:
1.
Remove the detector from its mounting plate:
If unmounted, hold the detector by its sides and push down on
the top end of the mounting plate, as shown at right.
If mounted, press the detector in the direction shown below.
o
o
o
C (32
F- 122
F)
Level 1 Setting
Level 2 Setting
Max.
Min.
Max.
Min.
20ft
3.3ft
10ft
6m
1m
3m
20ft
3.3ft
DO NOT USE
6m
1m
3.3ft
1m