DSC PowerSeries PC1616 Handbuch - Seite 7
Blättern Sie online oder laden Sie pdf Handbuch für Bedienfeld DSC PowerSeries PC1616 herunter. DSC PowerSeries PC1616 18 Seiten. System
enhancement
module
Auch für DSC PowerSeries PC1616: Installationshandbuch (17 seiten), Installationshandbuch (13 seiten), Kurzanleitung (4 seiten), Installationshandbuch (20 seiten)
DSC Power Series PC1616 PC1832 PC1864 System Manual
The system can generate two different alarm sounds:
Continuous Siren = Intrusion (Burglary Alarm)
Temporal/Pulsed Siren = Fire Alarm
Intrusion (Burglar) Alarm Continuous Siren
If you are unsure of the source of the alarm approach with caution! If the alarm was accidental, enter
your Access Code to silence the alarm. Call your central station to avoid a dispatch.
Fire Alarm Pulsed Siren
Follow your emergency evacuation plan immediately! If the fire alarm was accidental (i.e. burned toast,
bathroom steam, etc.), enter your Access Code to silence the alarm. Call your central station to avoid a
dispatch. Ask your alarm company if your system has been equipped with fire detection. To reset the
detectors, see the Sensor Reset section.
Trouble Conditions
When a trouble condition is detected, the Trouble or System indicator will turn on, and the keypad will
beep every 10 seconds. Press the [#] key to silence the beeps. Press [*][2] to view the trouble condition.
The Trouble or System indicator will flash. The corresponding trouble will be represented by numbers 1-
8.
LED/Digit Trouble Condition
Service Required
1
(Press [1] for more
information)
2
Loss of AC Power
3
Telephone Line Fault The system has detected that the telephone line is cut.
Failure to
4
Communicate
5
Sensor (or Zone) Fault The system is experiencing difficulties with one or more sensors.
Sensor (or Zone)
6
Tamper
Sensor (or Zone) Low
7
Batt
8
Loss of Time & Date
Trouble Menu Acknowledgement
https://alpha.adt.com/help/61[11/12/2018 9:40:17 PM]
Comments
(1) Low Batt (2) Bell Circuit (3) System Trouble (4) System Tamper (5)
Modulate Supervision (6) RF Jam Detected (7) PC5204 Low Batt (8)
PC5204 AC Failure
If the building and/or neighborhood has lost electrical power, the
system will continue to operate on backup for several hours.
The system attempted to communicate with the monitoring station, but
failed. This may be due to Trouble 3.
The system has detected a tamper condition with one or more sensors
on the system.
If the system has been equipped with wireless sensors, one or more
has reported a low battery condition.
If complete power was lost, the time and date will need to be re-
programmed.