Specifications and Features
S
1.1
Specifications
In order for the PC5928 module to operate properly, the power output capability
from the two AUX terminals combined must not be exceeded. Use the data
presented below to ensure that the PC5928 module is not overloaded when
connecting audio stations.
PC5928 Audio Interface Module
• Standby Current Draw - 65 mA
• Maximum Current Draw - 100 mA
• Total current providing capability
between AUX terminals - 500 mA
• Input Impedance at any
microphone input - 25kΩ
• Maximum Music Input signal level
amplitude - 200 mV peak to peak
• Connect up to 7 Audio Stations
(interior or exterior)
• Page Function
• Monitor Function
• Answer Incoming Calls
• Alarm Output Follower
As the number of intercom stations increases on the system, an additional
power supply may be required.
1.2
Additional Devices
PC5921 Interior Audio Station
The PC5921 Interior Audio Station is used in conjunction with the PC5928 Audio Interface
module. Each station has a separate microphone and speaker.
Each station must be home run to the interface module using shielded 22 gauge, 4
conductor wire. Each station can be used to initiate or receive pages, answer incoming
calls, answer the doorbell, monitor rooms or sound an alarm follower.
PC5921EXT Exterior Audio Station
The PC5921EXT Exterior Audio Station is housed in a gray fade resistant case, designed for
outside use. Each station has a separate microphone and speaker.
Each station must be home run to the interface module using shielded 22 gauge, 4 conductor
wire. The station can be used to sound the doorbell chime on interior audio stations.
PC5921EXT/R Exterior Audio Station
The PC5921EXT/R Exterior Audio Station is housed in a gray fade resistant case, designed
for outside use. Each station has a separate microphone and speaker.
Each station must be home run to the interface module using shielded 22 gauge, 4 conductor wire.
The station can be used to sound the doorbell chime on interior audio stations. A relay is included
so the normal doorbell can be used, instead of the one integral to the PC5928 module.
PC5904 Central Station Talk/Listen Module
The PC5904 Interior Central Station Talk Listen module is used in conjunction with the
PC5928 audio interface module for Talk/Listen-In purposes. While all other station types can
provide Talk/Listen-In capabilities, this station provides an added level of volume to the
central station operator's voice. Each station has a separate microphone and speaker. Each
station must be home run to the interface module using Shielded 22 gauge, 4 conductor
wire. All stations can be used to sound an alarm follower.
E
C
T
I
PC5921 Interior Audio Station
• Standby Current Draw - 20 mA
• Maximum Current Draw - 50 mA
• Built-In Speaker and Microphone
PC5921EXT Exterior Audio Station
• Standby Current Draw - 20 mA
• Maximum Current Draw - 50 mA
• Built-In Speaker and Microphone
PC5921EXT/R Exterior Audio Station
• Standby Current Draw - 20 mA
• Maximum Current Draw - 50 mA
• Built-In Speaker and Microphone
• Relay Output for doorbell circuit connection
PC5904 Central Station Talk/Listen Module
• Standby Current Draw - 30 mA
• Maximum Current Draw - 175 mA
• Built in microphone and 3.5 in. speaker