DSC ELECTRONICS 61XXX Series Benutzerhandbuch - Seite 10

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Bedienfeld DSC ELECTRONICS 61XXX Series herunter. DSC ELECTRONICS 61XXX Series 11 Seiten.

DF-C 63XXX & 61XXX Series User's Manual
Version 28.04.2019
Communication Protocol for DF-C63XXX Series Power Supplies
Interface: RS-232 (9 pin female) / RS-485 (2 pin male)
Command format: Asynchronous, 1start bit, 8 data bits, 1 stop bit
Baud rate: 9600
Communication mode: ASIIC code, "X" stands for numbers.
Termination: Each command sent by the power supply as reply is terminated with a ";"
Command
Function
#G
Output START
#U
Output STOP
#D
Read the output status
#SXXXX
Set the output parameter. The first 4 digits are the
XXXX
frequency value (resolution 0.1Hz). The last 4 digits are the
(S followed by
voltage setting (resolution 0.1V). The number "0" cannot be
8 data digits.)
omitted in the command. For example setting the
parameters 101Hz 62V would result in: #S10100620
#H
Switch to FS (0 – 300V) mode
#L
Switch to LV (0 – 150V) mode
#R
STOP output and CLEAR alarm
#C
Read the status of the power supply
Response
Received
Error
Received
Error
XXX.XHz;A:XXX.XV
XXX.XAXX.XXkW; B:XXX.XV
XXX.XAXX.XXkW;
C:XXX.XV
XXX.XAXX.XXkW
Error
Received
Error
Received
Error
Received
Error
Received
000
001
002
005
006
007
DSC-Electronics Germany • Georgstraße 36 • 53111 Bonn
DSC-Electronics Germany • Georgstraße 36 • 53111 Bonn
Description
The command is accepted
The power supply is not in standby mode or output may be
already active
The command is accepted
The power supply output is not active
The reply is a sequence of output frequency, voltage, current
and power. For example:
060.0Hz;A:090.0V010.0A00.90kW;B:090.0V010.0A00.90kW;C:
090.0V010.0A00.90kW.
The power supply output is not active
The command is accepted
The power supply is not in standby mode, or the parameter
exceeds range
The command is accepted
Wrong command
The command is accepted
Wrong command
The command is accepted
Standby mode
Started
Setup mode
Short circuit alarm
Over temperature alarm
Over current alarm