4.7 Changing the Frequency Band for your Region

Your Starter Kit has been shipped to you operating the European DECT Band (1880-1900MHz). In
this section instructions are given to reconfigure your system to operate in the DECT band allocated
by your local regulator:
Step 1: Steps 2-6 are for modifying the ULE Node Band setting. This setting will take effect upon
powering down then up the Node.
Step 2: Go the ULE Controller GUI Main Window and Open HAN Test Window
Step 3: Click the Tx Request Button in the HAN Test Window – Link Status should show "requested"
Step 4: Go the VAR Window and Send Tamper – Link Status in HAN Test Window should now
indicate "In Link" – as shown below
Step 5: Enter Value Length and Start address, Value for your Region (see table below, example given
is for transitioning to US) and hit "Set" button. Confirm change with the Get button. Now power
Down the Node
Step 6: Now for the ULE Controller Side. Close the HAN Test Window and return to the Main
Window and Click on the EEPROM Read/Write button at upper right
Step 7: You will get the EU value of 0x00. Now go to Write section and enter 0x20 for Start Adress
and Value of region – 0x01 in case of the US. Hit the Write EEPROM and Confirm change with the
Read EEPROM. Power Down and Up the Controller
Step 8: Power Up the Node and send a Tamper message to the Controller. Confirm that it succeeds!!
4.7.1 Offset 0x204 (Node) and Offset 0x20 (Controller) Values for changing Frequency
Band
Rev1.0
June 2015
14