3nStar BC1005 Technisches & Service-Handbuch - Seite 2

Blättern Sie online oder laden Sie pdf Technisches & Service-Handbuch für Kassenschalter 3nStar BC1005 herunter. 3nStar BC1005 8 Seiten. Bill counter
Auch für 3nStar BC1005: Technisches & Service-Handbuch (12 seiten)

Self Detection
E-26
E-27
E-32
E-30
E-29
Alarm Codes
E-17
E-18
E-11
E-23
E-22
E-15
E-33
E-10
SELF DETECTION CODES:
E26
1. Please check if counting sensor's plug is well connected to mainboard?
2. If it is well connected, please change the mainboard (with normal mainboard).
3. If normal mainboard has been changed but still not working, then change left
counting sensor.
E27
1. Please check if counting sensor's plug is well connected to mainboard?
2. If it is well connected, please change the mainboard (with normal mainboard).
3. If normal mainboard has been changed but still not working, then change right
counting sensor.
E32
1. Please check if speed sensor's plug is well connected to mainboard?
2. If it is well connected, please change the speed sensor (with normal sensor).
3. Check disk and make sure it is not deformed. If it is deformed, please change
the disk.
4. If still not working, then change mainboard.
ERROR CODE & SOLUTIONS
Problem Reason
Left Counting Sensor
Right Counting Sensor
Speed Sensor
Stacker Sensor
Hopper/Fedding Sensor
Meaning
UV Detection
MG Detection
Double Note Detection
Chain Note Detection
Slant Note Detection
Dimension Detection
Half Note Detection
Jam Detection
Solution