Airton 409709 Installations- und Betriebsanleitung - Seite 16
Blättern Sie online oder laden Sie pdf Installations- und Betriebsanleitung für Klimagerät Airton 409709 herunter. Airton 409709 17 Seiten. Monobloc mobile cold & hot air conditioner
7.TROUBLESHOOTING
Problems
met
The air conditioner does
does not work
The effect of
cooling or
heating is not
not optimal
Too noisy
The compressor does
does not work
The remote control
does not work
In case of abnormal situations, turn off the air conditioner and pull out the plug, then contact a
professional electrician for help.
ERROR CODE
E1
E2
E4
cause
The air conditioner is not powered
The water tank "FL" indicator
lights up
In cooling mode, the room
temperature is lower than the set
temperature; in heating mode, the
room temperature is higher than
the set temperature.
In dehumidification mode, the
room temperature is low.
Direct sunlight
The door and windows are open,
there are many heat sources in the
room.
The filters are too dirty.
The air inlet or outlet is blocked
The air conditioner is not placed on a
suitable installation surface
Compressor safety
protection engages
The distance between the air conditioner
and the remote control is too far and/or
the remote control is not aligned towards
the receiver
The batteries are exhausted
Fault in the pipe temperature sensor (probe)
Fault in the ambient temperature sensor (probe)
ANTI-FREEZE protection: the temperature of the pipe is too low and the air conditioner turns
off.
As soon as the temperature exceeds 8°C, the protection cuts out and the
initial programmed operating state is restored.
Solution
Turn it on after connecting it to an electrical
outlet
Empty the water by draining the air conditioner, then
restart the air conditioner
Change temperature settings
The air conditioner is placed in a room with an
ambient temperature above 17℃
Draw the curtains
Close the door and windows, remove
heat sources.
Clean or replace filters
Check air inlet and outlet, clear
obstruction
Place the air conditioner on a flat and rigid
surface, avoid any surface that causes
shaking
Wait 3 minutes, then restart the air
conditioner after the temperature drops.
Bring the remote control closer to the air conditioner
and make sure to point the remote control in the
direction of the receiver.
Replace the batteries
DETECTION
16