Attic Breeze AB–6062 Installationshandbuch - Seite 2

Blättern Sie online oder laden Sie pdf Installationshandbuch für Fan Attic Breeze AB–6062 herunter. Attic Breeze AB–6062 4 Seiten. Gen ii wm model series fans

Getting Started

Our wall mount solar fans have been carefully designed to provide easy installation with minimal tools or experience
required. Please consult your Attic Breeze dealer for more information regarding alternate installation methods.
Your local building code may require specific fasteners or anchoring systems not discussed in this installation
guide. If installing this product in an area of either Florida or Texas that has been designated as a high velocity
wind zone area, review applicable building code requirements for additional installation instructions.
What's Needed
Cordless Drill with Nut Driver
Self-Tapping Screws with Rubber Bonded
Washers
Reciprocating Saw
Measuring Tape

Safety Information

Safety precautions should be taken when performing the roofing work described in this installation guide. You can
significantly reduce your risk of danger by following the below recommendations:
• Do not perform roofing work in wet or windy conditions
• Tie-off both yourself and your equipment when working on steep pitched roofs to avoid falls
• Wear safety glasses and protective gloves when using power tools
• Always wear slip-resistant shoes when working on the roof
• Do not cut through any rafters or structural members of the roof during installation
• Leave the solar panel covered until your installation is complete
Choosing the Right Location
Choose a location on your roof to install the solar panel that will offer optimum sun exposure throughout the day. For
best results, pick an area that is oriented in a southern direction and is not shaded or otherwise blocked from the sun
for extended periods. If an installation location on the southern side of your roof is not available, please consult your
Attic Breeze dealer for additional solar panel mounting options.
Your solar attic fan should not be installed any closer than within 10 feet to an existing passive vent, ridge vent, or
additional fan unit. If installed in combination with a ridge vent, it may be necessary to block off a portion of the vent
close to the fan to achieve optimum attic ventilation performance.

Ventilation Requirements

In order for your Attic Breeze solar attic fan to operate at maximum performance,
your attic must have enough intake ventilation (net free area) to support the
amount of air that your fan is moving. The minimum recommended amount of
intake ventilation for your product model is shown in Table 1. Your installation
should either meet or exceed these recommendations for optimum fan
performance. If you need assistance determining the proper amount of intake
ventilation for your home, please visit our website for more information.
Weatherproof Roofing Grade Sealant
Lumber (2x4)
Ladder
Marker or Carpenter Pencil
Fan Model
AB-2062
AB-3062
AB-4062
AB-6062
Table 1 - Intake Ventilation Requirements
Intake Ventilation
4.7 sqft
5.7 sqft
6.3 sqft
7.0 sqft