3onedata IES2210-8P2GC-2P48-240W Handbuch zur Schnellinstallation - Seite 3

Blättern Sie online oder laden Sie pdf Handbuch zur Schnellinstallation für Schalter 3onedata IES2210-8P2GC-2P48-240W herunter. 3onedata IES2210-8P2GC-2P48-240W 3 Seiten. Unmanaged industrial ethernet switch

3onedata IES2210-8P2GC-2P48-240W Handbuch zur Schnellinstallation
Power input voltage of model VI model VII and model X:
48VDC, power input voltage of model I and model III: 48VDC
(12~48VDC).
AC power supply 220VAC
This series of model II and model IV
support AC single power supply and
provide 6 pins 5.08mm pitch input
terminal blocks, including 4 pins power supply terminal blocks
on the left side.
Power input voltage: 220VAC (85~264VAC).
【PoE Power Supply Pin Connection】
PoE port is powered by the following pins.
Pin
1
2
1
8
Definition
V+
V+
【Relay Connection】
The device provides 6-pin 5.08mm pitch input terminal blocks,
including 2-pin relay terminal blocks on the right side. Relay
terminals are a pair of normally open contacts in device alarm
relay. They are open circuit in normal non alarm state, closed
when any alarm information occurs. For example: it's closed
and sends out alarm when power off. The switch supports 1
relay alarm information and network abnormal alarm output, it
can be connected to alerting lamp, alarm buzzer, or other
switching value collecting devices for timely warning operating
staffs when alarm information occurs.
【DIP Switch Settings】
This series provide 4 pins DIP switch for
function settings, where "ON" is enable valid
terminal. DIP switch definition as follows:
DIP
Definition
Operation
1
Flow control
Set the DIP switch to ON, and
the device will enable flow
control
2
Port with the
Set the DIP switch to ON, and
specified
the 100M copper port of the
speed of 10M
device will be specified as 10M
DIP
Definition
3
Alarm
4
Reserved
【Checking LED Indicator】
The function of each LED is described in the table as below:
LED
P1/P2/PWR
3
6
V-
V-
ALM
RUN
Link/ACT
(1-4/8, G1-G2)
POE (1-4/8)
【Specification】
Panel
100M POE copper port
Operation
copper port
Set the DIP switch to ON, and
the device will enable port alarm
-
Status
Description
Power supply is connected
ON
and running normally
Power supply is
OFF
disconnected and running
abnormally.
ON
Port link alarm
OFF
Port link without alarm
The device is powered on or
ON
the device is abnormal.
The device is powered off or
OFF
the device is abnormal.
Blinking
System is running well.
Ethernet port connection is
ON
active.
Blinking
Data transmitted
Ethernet port connection is
OFF
inactive.
POE port supply electricity
ON
for other devices normally
POE is disabled or
OFF
disconnected
10/100 Base-T(X) RJ45,
automatic flow control, full/half
duplex mode, MDI/MDI-X
autotunning, POE port, the
output power consumption is
15W or 30W.
V+, V+, V-, V- are
POE pins
corresponding to 1, 2, 3, 6.
10/100/1000Base-T(X) or
Gigabit Combo port
1000Base-X
Console port
Reserved
6-pin 5.08mm pitch terminal
blocks, including 2-pin alarm
terminal blocks. It supports 1
Alarm interface
relay alarm information output,
current load capacity is
1A@30VDC or 0.3A@125VAC
Run indicator, interface
Indicator
indicator power indicator, alarm
indicator, PoE indicator
Exchange attributes
Backplane bandwidth
7.6G
Packet buffer size
1Mbit
MAC table size
8K
Power supply
Power supply input voltage:
48VDC, 24VDC, 220VAC
Input power supply
Support DC dual power supply
redundancy, anti-reverse
connection
6-pin 5.08mm pitch terminal
Access terminal
blocks, including 4-pin power
supply terminal blocks
Consumption
No-load
≤4.9W@48VDC
Full-load
≤122.8W@48VDC
Environmental limits
Working temperature
-40~75℃
Storage temperature
-40~85℃
Working humidity
5%~95% (no condensation)
Protection grade