3onedata IES3012G-8GT Handbuch zur Schnellinstallation - Seite 2

Blättern Sie online oder laden Sie pdf Handbuch zur Schnellinstallation für Schalter 3onedata IES3012G-8GT herunter. 3onedata IES3012G-8GT 3 Seiten. Unmanaged industrial ethernet switch

3onedata IES3012G-8GT Handbuch zur Schnellinstallation
Step 1
Check if the DIN-Rail mounting kit is installed firmly.
Step 2
Insert the bottom of DIN-Rail mounting kit (one side
with spring support) into DIN-Rail, and then insert
the top into DIN-Rail.
Tips:
Insert a little to the bottom, lift upward and then insert
to the top.
Step 3
Check and confirm the product is firmly installed on
DIN-Rail, then mounting ends.
【Disassembling DIN-Rail】
Step 1
Power off the device.
Step 2
After lift the device upward slightly, first shift out the
top of DIN-Rail mounting kit, then shift out the
bottom of DIN-Rail, disassembling ends.
Attention before powering on:
Power ON operation: first connect power line to the
connection terminal of device power supply, then power
on.
Power OFF operation: first unpin the power plug, then
remove the power line, please note the operation order
above.
【Power Supply Connection】
DC power supply
The series provide 4-pin power supply
input
terminal
independent DC power supply systems of
PWR1 and PWR2. The power supply
supports nonpolarity and anti-reverse
connection. It can normally operate after reverse connection.
Power supply range: 12~48VDC
【Relay Connection】
Relay terminals are a pair of normally open
contacts in the alarm relay of the device. They
are open circuit in normal non alarm state,
closed when any alarm information occurs. For example: it's
closed and sends out alarm when power off. This series
support 1 channel relay alarm information output, and DC
power alarm output. It can be connected to alarm indicator,
alarm buzzer, or other switching value collecting devices for
timely warning operator when alarm information occurs.
【DIP Switch Setting】
follows:
1.
Abnormal alarm settings of the
power supply connection
3.
Reserved
【Checking LED Indicator】
This series provide LED indicators to monitor the operating
status of the device, which can comprehensively simplify the
troubleshooting. The detailed status of each LED is described
in the table below:
LED
P1
P2
blocks
and
two
ALM/ALARM
RUN
Link/ACT
(G1-G8/G12)
This series provide 4-pin DIP switch for function
settings, where "ON" is enable valid terminal.
Please power off and power on after changing
the status of DIP switch. DIP switch definition as
2.
4.
Status
Description
P1 is connected and running
ON
normally
P1 is disconnected and running
OFF
abnormally.
P2 is connected and running
ON
normally
P2 is disconnected and running
OFF
abnormally
ON
Power supply link alarm
OFF
Power supply link without alarm
The device is powering on or
ON
running abnormally.
The device is powered off or
OFF
running abnormally.
Blink once per second, and the
Blinking
device is running well.
Ethernet port connection is
ON
active.
Blinking
OFF
【Specification】
Panel
Gigabit SFP
Gigabit copper port
Reserved
Console port
Reserved
Alarm interface
Indicator
Exchange attributes
Backplane bandwidth
Packet buffer size
MAC table size
Power supply
Input power supply
Access terminal
Consumption
IES3012G-4GS
Data transmitted
Ethernet port connection is
inactive.
1000Base-SFP, SFP slot
10/100/1000Base-T(X)
self-adapting RJ45 port, full/half
duplex self-adapting or specified
operating mode, support
MDI/MDI-X self-adaption
Reserved
2-pin 7.62mm pitch terminal
blocks, support 1 channel relay
alarm information output
Power supply indicator, running
indicator, interface indicator and
alarm indicator
24G
4Mbit
8K
12~48VDC
Support dual power supply
redundancy, nonpolarity and
anti-reverse connection
4-pin 7.62mm pitch terminal
block
No-load consumption:
4.85W@24VDC
Full-load consumption:
10.32W@24VDC