4.Specifications
Model (AD-)
Measurement range
Accuracy
Display
Measurement direction
Measurement
mode
Right peak / Left peak(P-P)
Battery-powered
Measurement unit
Charging time
Usage time
Battery life
Auto power off
Data output
Dedicated charger
Dimension
Net weight
Accessories
AD-TM1
TSS-5 / TC-2
AD-TM5
AD-TM10
TSS-10 / TC-3
TSS-30 / TC-6
AD-TM50
AD-TM100
TSS-30 / TC-4
AD-TM200
TM1
±1.000~
±10.00
N・cm
±100.0~
±1000
gf・cm
±0.100~
±1.000
lbf・in
PEAK
TRACK
The display changes as the torque value changes. Used for zero adjustment, etc.
Rechargeable more than 300 times (depending on usage conditions)
About172(L)×210(W)×55(75 with the measuring socket included) (H)
Attachments
TM5
TM10
±5.00~
±10.00~
±50.00
±100.0
N・cm
N・cm
±0.500~
±1.000~
±5.000
±10.00
kgf・cm
kgf・cm
±0.500~
±1.000~
±5.000
±10.00
lbf・in
lbf・in
±0.5% FS
4 Digits LCD
+ : Right rotation, - : Left rotation
Hold the maximum torque
Hold the left and right peak values.
Rechargeable Ni-MH Battery 1.2v×4cells (1650mAh)
Switchable 3 units: N・m(N・cm)/kgf・cm(gf・cm)/lbf・in
About 3 hours
About 12 hours in continuous use
Power off after being left for 10 min.
(Measurement without any time limit is also available)
ASCII format (Baud rate: 19200)
IN:AC100V~240V  OUT:DC9V
About 2.4kg
TM50
TM100
±0.500~
±1.000~
±5.000
±10.00
N・m
N・m
±5.00~
±10.00~
±50.00
±100.0
kgf・cm
kgf・cm
±5.00~
±10.00~
±50.00
±100.0
lbf・in
lbf・in
Others
AC adaptor(AD-20)
USB cable (AD-USB-1.5)
TM200
±2.00~
±20.00
N・m
±20.0~
±200.0
kgf・cm
±20.0~
±200.0
lbf・in