WARNING: Do not allow sealants containing acetic acid
(smells like vinegar) such as silicone rubber sealant to contact the
plastic pump housing or thru-hull connector. Such sealants can
attack the plastic, causing the pump housing to crack, resulting in
pump failure.
5. Insert thru-hull connector through the hole and tighten to hold
the thru-hull connector firmly in place. CAUTION: Do not
overtighten the nut.
WIRING INSTRUCTIONS
WARNING: Be certain that power source is 12-volt D.C. Higher
voltage will damage the pump.
1. Using the full length of wire provided (and additional wire if
necessary), connect wires to the pump as shown in the
diagram. (See Figure 2.)
Figure 2
12 Volt Battery
Suitable Fuse
(see chart)
2. Route wires out of the way and secure them to the bulkhead to
avoid pulling.
3. Using butt connectors sized for 16-gauge wire, splice fuse
holder into positive lead (brown) between the battery and switch.
Position fuse holder in a location that is easily accessible for
changing fuses.
IMPORTANT: Use fuses of the proper amperage (See Specification
Chart at top of sheet).
WARNING: FAILURE TO PROPERLY FUSE AND MAKE THE
APPROPRIATE WATERPROOF CONNECTIONS WILL VOID THE
PRODUCT WARRANTY.
4. Install a Three-Way Switch (Attwood No. 7615A) that allows for
automatic or manual switching modes.
5. Turn the pump on and twist the Test Knob clockwise to check
operation. Feed water into the pump. If output appears to be too
low, check the wire connections. Reversed connections result in
opposite impeller rotation that drastically reduces capacity and
can cause premature pump failure.
CARE AND MAINTENANCE
Occasionally check your pump to be certain debris is not jamming
the impeller and/or float within the housing. Use the test knob by
rotating in a clockwise direction. Careful attention will guarantee
outstanding pump performance.
To clean the water chamber, remove pump housing from the mounting
base by pressing in tabs on sides. Lift the pump housing away.
(See Figure 3.)
To clean the impeller, remove the impeller guard screw and lift the
impeller guard.
Black
Brown/White or Tan
Manual
Off
Brown
Automatic
Test Knob
3-Way Switch
#7615A
Figure 3
Remove (1)Screw
Remove all debris that has accumulated in pump chamber and
around the impeller. Ensure that all debris is removed from strainer
slots around the pump base.
Inspect the impeller to ensure that it is firmly attached to shaft and
is not cracked or broken.
Replace impeller guard, screw, and pump housing on base. Be
certain that all tabs are fully engaged.
Periodically check the electrical connections to ensure they are
water-resistant and mounted high and dry.
Do not use household cleaners on the pump because many of
them may damage the pump materials.
ATTWOOD LIMITED WARRANTY
ATTWOOD CORPORATION, 1016 North Monroe, Lowell, Michigan 49331
("Attwood") warrants to the original consumer purchaser that Attwood brand
products will be free from defects in materials and workmanship under
normal use and service for three years from the date of original consumer
purchase. This warranty does not extend to any batteries or fuses used with
the product. This limited warranty is not applicable if the product has been
damaged by accident, improper installation, unreasonable or improper use,
lack of proper maintenance, unauthorized repairs or modifications, normal
wear and tear, or other causes not arising out of defects in materials or
workmanship. Attwood products are warranted for use on pleasure boats.
Any other use — including but not limited to commercial, racing, or non-
marine use — are not covered under this warranty. Attwood's obligation
under this warranty is limited to repair of the product at Attwood's plant or
replacement of the products at Attwood's option without expense to the
original consumer purchaser. Any expenses involved in the removal,
reinstallation or transportation of the product are not covered by this
warranty. The product must be returned to Attwood's plant at the address
above, postage prepaid, and insured with proof of original purchase
including date. If Attwood is unable to replace the product and repair is not
commercially practical or cannot be timely made, or if the original consumer
purchaser is willing to accept a refund in lieu of repair or replacement,
Attwood may refund the purchase price, less an amount for depreciation.
The acceptance by Attwood of any product returned or any refund provided
by Attwood shall not be deemed an admission that the product is defective
or in violation of any warranty. Products that are replaced or for which a
refund is issued become the property of Attwood.
THIS WARRANTY IS ATTWOOD'S ONLY EXPRESS WARRANTY OF
THIS PRODUCT. NO IMPLIED WARRANTY SHALL EXTEND BEYOND
THREE (3) YEARS FROM THE DATE OF ORIGINAL CONSUMER
PURCHASE. ATTWOOD SHALL NOT BE LIABLE FOR ANY DAMAGES,
FOR LOSS OF USE OF THIS PRODUCT, NOR FOR ANY OTHER
INCIDENTAL OR CONSEQUENTIAL DAMAGES, COSTS OR EXPENSES.
Some states do not allow limitations on how long an implied warranty lasts
or the exclusion or limitation of incidental or consequential damages, so the
above limitations and exclusions may not apply to you. This warranty gives
you specific legal rights, and you may have other rights which vary from
state to state.
© 2003 Attwood Corporation
1016 N. Monroe Street, Lowell, MI 49331-0260 www.attwoodmarine.com
Impeller Guard
Depress (2)Tabs