DTM System UVR-2 Betriebshandbuch

Blättern Sie online oder laden Sie pdf Betriebshandbuch für Empfänger DTM System UVR-2 herunter. DTM System UVR-2 2 Seiten.

V. Examplary electric scheme
L
230V AC
N
Channel 2 manual
Control button
Channel 1 manual
Control button
IN1
IN1
IN2 IN2
Fig.3 UVR-2 receiver and electrical devices conection exemplary scheme
VII. Warranty
DTM System checks all the devices before shipping. The
warranty time is 24 months from the selling date. This time
is counted according to the warranty label. The
manufacturer will fix all the problems which come because
of his fault. Non functioning device should be delivered
back to the distributor with short problem description. The
cost of mount/dismount is covered by user. The warranty
do not cover: batteries in the remotes, faults caused by
improper usage, user self repairs and adaptations,
lightning strikes, over voltages or short circuits in the
mains supply. Appropriate legal acts regulates details of
the warranty.
The intention of the WEEE Directive
(Directive 2002/96/EC on waste electrical
and electronic equipment) is to reduce the
amount of hazardous substances in waste.
The underlying purpose is to promote the
avoidance, recovery and risk-free disposal
of waste.
ELECTROLOCK
OR OTHER LOW VOLTAGE
DEVICE
230v SUPPLIED
DEVICE
~230V
NO1
C1
NC1 NO2
C2
NC2
UVR-2 RECEIVER
VII. Declaration
4
UVR-2 Receiver Operating manual
I. Used terms
Monostable output mode – turn on for programmed time after pushing the button
4
Bistable output mode – switch to opposite (turn on or turn off) after pushing button
4
4
Momentary output mode – turn on as long as the button is being pushed
Manual control – operating controled by momentary buttons connected to UVR-2 board.
4
12V AC
II. General information
Remote control receiver
UVR-2
230V loads, up to 600W. UVR-2 is compatible with DTM remotes. Exemplary application: control of gate automatic,
pomps, lightning, alarm system and more.
III. Technical data
4
receiver supply 230 V AC
4
superherterodyne receiver, work frequency: 433.92 MHz,
4
dynamically variable code Keeloq gives high class safety
4
two separated relay outputs, NO or NC, max load for each output 600W
4
max peak current 16A/230V AC
4
two manual control inputs
4
three working mode: bistable, momentary, monostable (1s resolution for times up to 1 minute and 1min resolution for
times from 1min to 127min)
4
discretion with ascribing remote buttons to receivers outputs
4
hardware interface with 6 diodes
4
receiver's memory containing 35 remote controls of ZSP series
4
remote radio range up to 150m
4
single remote removing possibility
4
working temperatures from -20 C to +55 C
4
two enclosure versions: surface mounted, inside mounted, IP55
4
dimensions: surface mounted enclosure: 89 x 89 x 52 mm or install box of 80 mm diameter, 40 mm depth
IV. Receiver installation
This installation should be made by a qualified service person and should conform to all local codes.
Turn all power off while installing. System should be installed with safety, to minimalize potential risk of using.
1. Device description and installation
Receiver consists of main board and case. Main board contains: power supply, microprocessor user interface
with LED diodes, buttons and jumper, executive circuit on two relays, terminal blocks for: power supply, controlled
was made for universal use – remote or manual control of electrical devices of heavy
CAUTION!!
Device is designed to operate with high voltages.
Fitter is responsible for any presumptive damages.
1
1
Made in
Poland