Aube Technologies TI032-3W Installationsanweisungen und Verwendung
Blättern Sie online oder laden Sie pdf Installationsanweisungen und Verwendung für Schalter Aube Technologies TI032-3W herunter. Aube Technologies TI032-3W 2 Seiten. Aube technologies inc. programmable wall switch installation and user guide
Auch für Aube Technologies TI032-3W: Installations- und Benutzerhandbuch (2 seiten)
http://waterheatertimer.org/Programmable.html#Aube
1 . Introduction
The TI032-3W programmable wall switch is
designed to control lighting loads such as incan-
descent, halogen, low voltage halogen with trans-
former, and fluorescent lights.
It features seven (7) ON/OFF programming
sequences which can be programmed daily or
weekly. The wall switch also includes a manual
override that can be activated at any time.
The timer may be used for a single pole, an exist-
ing 3-way switch or a new 3-way switch installa-
tion.
2. Installation
This wall switch can be used for either single pole
or multiswitch installation.
A multiswitch installation with an electronic wall
switch differs from conventional installation.
Read wiring instructions carefully and follow
guidelines applicable to your installation.
2.1 Guidelines
TURN OFF POWER AT THE MAIN POWER
PANEL TO AVOID ELECTRICAL SHOCK.
THE MAXIMUM LOAD MUST NOT EXCEED
500 W @ 120 V (MIN 40 W).
• The wall switch must be mounted onto a stan-
dard single or multi-gang electrical box.
• Avoid locations where ambient temperature
can exceed 50°C (122°F).
• Do not clean the timer with a solvent or an
abrasive cleaner; use a lint-free cloth and a
mild soap.
2.2 Installation Procedure
If you are replacing an existing switch,
remove the switch. For an existing 3-way
installation, identify the wire connected to the
"common" screw.
Reconnect each disconnected wire to the
new programmable wall switch according to
your application.
Push the wires into the electrical box leaving
space for the timer and secure the timer
using the provided screws.
Install the wall plate (not included).
Return power at the circuit.
Power-on the switch and test the operation
of the switch(es). See Power-On and Test
Installation section for information.
NOTE:
See also the Troubleshooting section.
N O TE A:
Th e wh i te wi re i s n ot th e n eu tral
wi re bu t th e wi re g oi n g to th e load .
2.3 Single Pole Installation
When installing, ensure wire "2" is connected with the line wire identified as "C".
2.4 Existing 3-way Installation
The "common" wire, previously identified upon removal of the old switch, must be con-
nected to the "C" wire of the programmable wall switch. Connect the two other wall
switch wires to the two remaining wires (see above).
Connect the supplied jumper wire from the "common" terminal screw to the screw ter-
minal where wire "1" of the wall switch is connected.
2.5 New 3-way Installation
For a new installation, a single pole switch can be used at the remote location. Refer
to the following wiring diagram:
NOTE:
The provided jumper wire is not used for this type of installation.
3. Power-On and Test Installation
Open the cover using a small flat tip screwdriver.
Set the ON/OFF switch to ON.
RESET using a pointed object (e.g. paper clip).
The screen should display: 0:00, MO, MAN and
OFF.
If the screen is blank, check the following:
a) The ON/OFF switch may not be engaged in
the ON position; try pushing it further to the
right.
b) If the wall switch controls a lamp equipped with its own ON/OFF switch,
ensure the lamp switch is ON.
c) If the wall switch only controls one light bulb, turn the switch OFF and check if
the light bulb is good and tightly screwed in its socket.
Once the screen is back on, test the installation.
TI032-3W / 3-WAY
Programmable Wall Switch
I n stall ati on I n stru c ti on s