Figure 5. How to remove the sensor.
3) Programming the temperature profile.
A total of 6 steps can be programmed with this controller. Each step contains the
temperature (C0X) and time duration (T0X) setting. They are represented by the symbol
C0X and T0X, where "X" is the step number (e.g. Step 4 temperature is represented by
C04 and step 4 time is represented by T04). The character, "T", is displayed as the
symbol, " ". Time is defined as the duration between the last step and the next step.
Please make sure the time is long enough for the heater to heat up the oven. If the time
is set too short, the temperature may not be able to reach the current step temperature
setting, before it jumps to the next step. The time unit is in minutes with 1 minute
resolution. If the recipe only needs one step, you can program the time of the rest of the
steps to zero.
To program the temperature profile, press SET key once. The display will show C01 for
one second and then display the temperature setting for step 1. Use "+" and "-" keys to
change the temperature setting. When finished, press the SET again to confirm the
change. The display will show T01 for a second and then change to the cook time setting
for step 1. Use "+" and "-" keys to change the cook time setting. When finished, press the
SET again to confirm the change. The display will go the step 2 setting. The following is
the flow chart for the setting procedure.
6