Multi-Viewer Switch API
Note: At this point, the device starts sending Keep-Alive events, every five seconds.
Keep-Alive events are transmitted by the switch periodically to communicate the current configuration.
For example, to switch to Channel 4, the user types: #AFP_ALIVE F7
Then, every five seconds, the device sends the following keep-alive event: 00@alive fffffff7 as shown in
Figure 4.
The interval time of keep-alive events can be changed, using the #ANATA command followed by a time
period operand in units of 0.1 second. Thus:
#ANATA 1 gives an interval of 0.1 seconds
#ANATA 30 gives an interval of 3 seconds

Command Structure

The command structure is comprised of the following 4 fields:
MAN-000023
Figure 3: PuTTY Session Settings
Figure 4: Keep-Alive Events