9. FAQ (frequently asked questions)
Question
Cause
No voltage supply
The actuator is not
operating
With voltage supplied
The window opening is not
as required
The actuator is not travel-
ling the distance required
The chain is bent and not
perfectly linear
Fixings (bottom-hung
The actuator pulls out the
window and/or top-hung
screws
window) are no longer faste-
ned to the frame
Remedy
Check the electrical cut-out or safety
switch is "On".
A cable may not be connected. With volta-
ge supplied | Check the actuator voltage
corresponds to voltage supply detected.
Check the actuator voltage corresponds
to voltage supply detected
Check that according to the table on
Page 13 the DIP-switches are set for the
correct travel.
Detach the chain from the fixing and
check that the limiting arm allows the
actuator to travel the complete run. If
this does not happen, adjust the limiting
arm so that the actuator travels the
whole distance..
Check that suitable fixings have been
used.
Check that, on closing, the chain is
perfectly perpendicular to the frame. If
not, check that the fitting was carried out
according to the Installation Sequence,
5.1.
39