14) Firmware v1.1: 05/2016
1) NEW FEATURES
•
External clock resolution can now be selected from 1, 4 or 24 PPQN.
•
The ADE-32 now has two clock modes. Choose between internal clock mode where the ADE-32
runs from its own internal clock or external clock mode where the ADE-32 will not run unless a
clock source is present at the external clock input.
•
Switching clock modes when no external clock is present can be used for manual stop/start control.
•
The 2 blue bar/beat LEDs reverse out to show when the ADE-32 is running under external clock.
•
Each output can now be muted individually. The blue edit LED flashes to indicate a muted state
on the currently selected output.
2) CHANGES
•
Quantized (0-1V) or unquantized (+/-5V) S&H CV types can now be set locally, per output.
•
Pulses, gates and loops are now unipolar 0-5V.
•
Gate 1 and 2 lengths are now 1/16, 4/16, 8/16 and 12/16 respectively.
•
LED indicator behaviour standardised to 3 flashes for all option and global settings.
3) BUG FIXES
•
Fixed a bug where pulses would not trigger at clock divisions greater than 16 || 4.
•
Fixed a bug where output types 9-10 might act eratically when allocated to output 8.