Auber Instruments TS-DR-110 Gebrauchsanweisung
Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Schalter Auber Instruments TS-DR-110 herunter. Auber Instruments TS-DR-110 3 Seiten. Din rail mounted programmable digital timer switch
AUBER INSTRUMENTS
Instruction Manual
DIN Rail Mounted Programmable Digital Timer Switch
1. Overview
This is a programmable digital timer switch with relay output. It can be used to
switch on or off lights, appliance, or other small loads at specified date and
time. The timer can be programmed to turn on/off the relay in 17 different daily/
weekly schedules. Manual mode is available to overrule the programmed relay
events. A 1.2 V / 40 mA lithium battery inside the timer switch provides power
to the timer and it will be charged whenever the switch is connected to an AC
power. The DIN rail mount of this timer switch makes it suitable for power
management in a control panel.
2. Specifications
Table 1. Specifications
Power supply voltage rating
Power consumption (MAX)
Display type
Relay lifetime
Load capacity
Output relay
Timer range
Timer deviation
Power-off memory
Working temperature
Ambient humidity
Power reserve
Size
Weight
3. Dimensions
Figure 1. Dimensions of TS-DR-110 / TS-DR-12.
2021.07
(TS-DR-110 / TS-DR-12)
110 VAC or 12 V AC / DC
2 W
LCD
Mechanically 10,000,000;
Electrically: 100,000
Resistive load: 16 A / 250 V AC;
Lagging load: 8 A / 250 V AC;
Lamp Load: 2000 W
1 x form C relay (1 N.O., 1 N.C.)
1 minute ~ 168 hours (7 days)
+/- 1 second / 24 hours, 25° C
60 days
-14° F ~ 104° F ( -10° C ~ + 40° C)
35 - 85% RH
3 years (lithium battery)
86.5 mm x 36 mm x 65.5 mm
120 g
Version 1.1 (Jul, 2021)
4. Wiring Diagrams
Figure 2(a). Wiring for 110V AC version TS-DR-110.
Figure 2(b). Wiring for 12V DC version TS-DR-12.
WWW.AUBERINS.COM
P1/3