Dametric BRM-DM1 Installationshandbuch - Seite 5
Blättern Sie online oder laden Sie pdf Installationshandbuch für Kontrolleinheit Dametric BRM-DM1 herunter. Dametric BRM-DM1 6 Seiten. Gms basic refiner module
Auch für Dametric BRM-DM1: Benutzerhandbuch (10 seiten)
Dametric AB
5.6 Connector J4, POM, VIM, TVD
1
POM-T1
2
POM-T2
3
POM-T3
4
POM-T4
5
POM-T5
6
POM-T6
7
0VDC
8
0VDC
9
VIM-EP
10
VIM-SP
11
VIM-SN
12
VIM-EN
13
0VDC
14
0VDC
15
TVD-EP
16
TVD-SP
17
TVD-SN
18
TVD-EN
19
0VDC
20
0VDC
5.7 Connector J5, HPM, OTM, AIN
HPM-A and HPM-B measures two pressure transmitters.
1
HPM-SAP
2
HPM-SAN
3
HPM-SBP
4
HPM-SBN
5,6
0VDC
OTM-1 and OTM-2 measures PT100 sensors in a 3-wire connection.
The compensating and negative wires are internally connected in the transducer end.
7
OTM-E1
8
OTM-S1
9
OTM-N1
10
0VDC
11
OTM-E2
12
OTM-S2
13
OTM-N2
14
0VDC
15,16
0VDC
MPM and AIN measures active 4-20mA input signals, that is – the electrical current loop is not
powered from the BRM unit.
17
MPM-IP
18
MPM-IN
19
AIN-P
20
AIN-N
5.8 Connector J11, Ethernet
RJ45 connector for the Ethernet cable.
Connect the cable to the switch of the local GMS network.
5.9 Connector J12, USB
USB-A connector for a memory stick.
BRM-DM12 IM EN.docx
BRM-DM1/2
K-POT25/white (to POT-50 transducer)
K-POT25/brown
K-POT25/green
K-POT25/yellow
K-POT25/grey
K-POT25/rose
K-POT25/shield
Signal ground
K-VIMS25/white (to VIM-T2 transducer)
K-VIMS25/brown
K-VIMS25/green
K-VIMS25/yellow
K-VIMS25/shield
Signal ground
K-TVDS25/white (to TVD-T2 transducer)
K-TVDS25/brown
K-TVDS25/green
K-TVDS25/yellow
K-TVDS25/shield
Signal ground
HPM-A, Analog input, positive, 4-20mA
HPM-A, Analog input, negative, 4-20mA
HPM-B, Analog input, positive, 4-20mA
HPM-B, Analog input, negative, 4-20mA
Signal ground
OTM-1, Excitation, PT-100
OTM-1, Compensation, PT-100
OTM-1, Negative, PT-100
Signal ground
OTM-2, Excitation, PT-100
OTM-2, Compensation, PT-100
OTM-2, Negative, PT-100
Signal ground
Signal ground
MPM analog input, positive (4-20mA)
MPM analog input, negative (4-20mA)
Analog input, positive (4-20mA)
Analog input, negative (4-20mA)
October 14, 2019
Installation manual
1
19
2
20
1
19
2
20
Page 5 of 6