Trouble shooting information
Error
Beeps-
Protection
Code
Buzzer alert
000
1 Beep
Resetting
Not reset
E00
No beep
completely
3 Beeps
when
operating,
Oveuse
E01
until it has
protection
completely
recovered
Unbalance
E02
2 Beeps
protection
No Beep,
reverses
40mm no
Anti-
E03
matter
collision
pressing the
button
No beep,
reverses
30mm no
Sensi touch
E04
matter
protection
pressing the
button
M1 motor
over
E11
5 Beeps
current
protection
M2 motor
over
E12
5 Beeps
current
protection
No beeps,
No hall
E21
screen
sensor from
flashes E21
M1
No beeps,
No hall
E22
screen
sensor from
flashes E22
M2
No current
E31
4 Beeps
from M1
No current
E32
4 Beeps
from M2
Situation
Press both up & down buttons at the
same time for 3 seconds. Continue
pressing the buttons until both
columns are in the lowest position.
When control box makes 1 beep
it is confirmed that reset has been
completed and buttons can be
released.
When reset is required but not fully
reset/completed.
Continuous running the frame for 300
seconds
will activate the overheat protection.
Difference between 2 motors over
10mm.
Detecting the variation in electronic
current motor will stop when
excessive variation detected in a
certain time.
Detecting if the system has collided
with an object, becoming uneven or
has shifted during operation.
When the column M1 is overloaded
or internal transmission is jammed.
When the column M2 is overloaded
or internal transmission is jammed.
Only current is detected, no hall
sensor.
Column is not moving.
Only current is detected, no hall
sensor.
Column is not moving.
No current is detected from column
M1.
1 Column is not moving and the other
column slightly shakes.
No current is detected from column
M2.
1 Column is not moving and the other
column slightly shakes.
Solution
Press both up & down buttons at the same time for
3 seconds. Continue pressing the buttons until both
columns are in the lowest position. When control box
makes 1 beep it is confirmed that reset has been
completed and buttons can be released.
Now the desk is opperational.
Press both up & down buttons at the same time for
3 seconds. Continue pressing the buttons until both
columns are in the lowest position. When control box
makes 1 beep it is confirmed that reset has been
completed and buttons can be released.
Now the desk is opperational.
The system will recover and after 75 seconds it is
possible to run the frame for 300 seconds again.
If the resting time or the interval time between
operations is too short, the next running time will be
reduced in order to give the system enough time to
cool down.
Press both up & down buttons at the same time for
3 seconds. Continue pressing the buttons until both
columns are in the lowest position. When control box
makes 1 beep it is confirmed that reset has been
completed and buttons can be released.
Now the desk is opperational.
Remove the obstacle and desk will become
opperational again.
Remove some load from your desk to lower the
current to operate the desk.
If the desk is still not operational, the nut might be
broken or the spindle/bracket might be damaged.
Change motor or motor cable.
Press both up & down buttons at the same time for
3 seconds. Continue pressing the buttons until both
columns are in the lowest position. When control box
makes 1 beep it is confirmed that reset has been
completed and buttons can be released.
Now the desk is opperational.
Check if the motor plug is well connected.