Elite Element DCM-120100C Gebrauchsanweisung

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Messgeräte Elite Element DCM-120100C herunter. Elite Element DCM-120100C 5 Seiten. Multi-function panel meter

Elite Element DCM-120100C Gebrauchsanweisung
Instruction Manual for Multi-function Panel Meter
Elite Element Model – DCM-120100C
Main Features of the Meter
Both forward (Positive) and reverse (Negative) current flows can be measured.
The "CHARGING" LED on the right lights when the battery is charging.
Other LEDs (V, TIME, W, A, AH, %) show what the display to the left is measuring.
The measured values are shown on two-line seven-segment multi-function displays:
On the top line is a four-digit display, toggled by the V/W button between
- Voltage (V), Power (W) and Working Hours (TIME)
On the bottom line is a three-digit display, toggled by the A/AH button between
- Current (A), Ampere-hours (AH) and Remaining Capacity Percentage (%).
There is a flexible calibration process for voltage, current and Amp-hours/ % capacity
The meter does not require external power when measuring between 10V and 90V.
The meter consumes very little power for its own operation.
The package includes the display unit, connector block and current-measuring shunt.
Specification
• Power supply required: DC 10 to 90V (external or internal)
• Measuring range:
(1) Using an external power supply - Voltage 0 to 120.0V / Amp 0 to 100A
(2) Using an internal power supply - Voltage 10 to 90.0V / Amp 0 to 100A
• Accuracy: Volts ± 0.1% + 2byte, Amps ± 0.5% + 3byte
• Resolution 0.01V, 0.1A, 0.01W, 0.01Ah
• Dimensions: 79mm x 43mm x 30mm
• Panel cutout: 76.5mm x 39.2mm
• Sampling rate: 5 reading per second
• Displays: 4 and 3 digits Red LED
• Operating Temperature: 0 to 50°C
• Operating Humidity: 35 to 85% Relative Humidity
• Weight: 130g including the shunt
(English version - edited)