Ethernet Transport Provider
7
Ethernet Transport Provider
7.1
General
The Ethernet interface supports the Transport Provider protocol, which allows a host to control
the network interface on the other side of the gateway using the standard Anybus-S API.
(Slave)
(Slave)
(Slave)
(Slave)
Fig. 13
Ethernet Transport Provider
7.2
Allocation of I/O Data
Example
I/O Size, Interface A = 30 bytes
I/O Size, Interface B = 20 bytes
Transport Provider I/O Size = 20 bytes - 10 bytes = 10 bytes
Fig. 14
Transport Provider example
If the Transport Provider shall handle the complete I/O image towards the other network, the I/O
size should be set to 0 (zero) on the Ethernet interface.
®
Anybus
X-gateway
™
PROFINET
(Other network)
Interface A
I/O Size = 30 bytes
20 bytes
10 bytes
10 bytes
®
IRT (2.32) Interface Network Guide
PROFINET (Ethernet)
OPC Server
Interface B
I/O Size = 20 bytes
This data is available as I/O Data
20 bytes
on the PROFINET (Ethernet) side
This data is transported as I/O Data
through the Ethernet Transport Provider
15 (18)