Ducati SW400 Handbuch - Seite 10
Blättern Sie online oder laden Sie pdf Handbuch für Toröffner Ducati SW400 herunter. Ducati SW400 11 Seiten.
DUCATI
How to install the actuator
4.2 Front mounting bracket: How to determinate the position where to install the
front mounting bracket
Warning: make sure not to use the full actuator stroke (save at least 1-2cm of
travel) as the gate wing must stop by pressing on a mechanical end limit (fixed on
the ground or FC integrated limit) before the actuator reaches the end of it's own
stroke travel (see page 8).
In case of telescopic actuator this allows to keep the telescopic tube more guided
when it is extroflexed, ensuring greater solidity.
Suggestion: if it is necessary to move the actuator forward or backward, the motor
can be powered directly with a 12V battery: connect the motor's two-pole cable to
the two poles of the 12V battery. By inverting the polarity the motor reverses the
direction of travel
Warning:
A) TELESCOPIC ACTUATORS,
featuring telescopic stainless steel telescopic tube are supplied with totally
retracted piston tube, therefore the fixing position of the front bracket to the gate
must be determined with the gate in open position* (in case of gate gate
opening towards inside the property)
or Vice versa in the case of a gate that opens outwards (push-to-open).
Resume of telescopic actuators models:
HC312; HC412; HC512; HC612; SW400T; EVO900T; EVE900T (+ corresponding
24V versions)
B) NOT TELESCOPIC ACTUATORS
are provided with running sleigh ( sliding shoe plate) positioned to the front of
the actuator, therefore the fixing position of the front bracket to the gate must be
determined with the gate in closed position* (in case of gate gate opening
towards inside the property)
or Vice versa in the case of a gate that opens outwards (push-to-open).
Resume of NON telescopic actuators models:
HC418; HC518,HC618, SW400; EVO900; EVE900 (+ corresponding 24V versions)
Fix the front bracket to the gate
- The actuator must be fastened to the front fixing bracket, keep it perfectly in line
with the gate wing
- bring the actuator to the gate leaf and identify the fixing point of the front plate to
the wing gate.
- Mark middle of front bracket slots on the gate wing.
- Fix the bracket on the gate. Use bolts anchors or screws suitable for the gate
(wood/ iron/...). It 'also possible to weld the bracket to the wing of the gate.
- Fasten the actuator to the bracket. Fix it with the pin and seal ring
- for "EVE actuators see page 23
- for telescopic "HC" actuators see page 24 drawing 19A
- for non- telescopic "HC" actuators see page 24 drawing 19B
- for telescopic "SW" and "EVO" actuators see page 25 drawing 25
- for non-telescopic "SW" and "EVO" actuators see page 25 drawing 24a/b
5. MANUAL RELEASE
The actuators are equipped with a release system which allows the manual handling
of the gate in case of emergency.
The release system is operated through the use of three-sided key that must be
inserted into the triangular slot.
Turn of about 180 ° up to the stop in a counterclockwise direction.
The actuators will be unlocked and the gate can be opened manually.
The reverse operation will restore the automatism traction.
Warning! perform the manual release only once the actuator is installed to the gate.
The manual release could be little bit hard in the beginning, but after a run-in period
will be smooth
- for EVE actuators see page 23
- for "HC" actuators see page 24
- for "SW" & EVO actuators see page 25
For "EVE" acuators the optional " EVE LOCK" manual release key protected
accessory is also available. see page 23 fig. 15B
For "SW & EVO acuators the optional " SW LOCK" manual release key protected
accessory is also available. see page 25 fig.26B
In order to have access to the release system from the outside, it is advisable to
create a secondary pedestrian passage, especially in the case where the gate does
not allow access from the outside to the system.
31