4. Installation criteria

To fix the automation system's "U" channel rail it is necessary to have a minimum clearance of 5 cm
between the ceiling and the space through which the door moves.
A minimum distance of 1 cm is necessary between the position of the "U" channel rail and the space
through which the door moves. See fig. 7
Fig. 5
MAXIMUM DOOR HEIGHT
Fig. 6
Retractable door
Power supply 230V - 50/60 Hz
Lifting force
= 100 N MAX
max.
h 2,30 m
Fig. 7
ceiling
rail
"U" channel rail
Sectional door
max.
h 2,15 m
rail=3 cm
Min. 1 cm
Drive head – geared motor unit complete with
circuit board
Manual release cable connected to the door handle
for external operation.
Set of photoelectric cells (optional accessory not
included in the kit)
Canopy door
IMPORTANT: for installation
on this type of door, optional
accessory 992012 is
necessary
max.
h 2,15 m
Page 5