Anyload EC100 Betriebshandbuch - Seite 5
Blättern Sie online oder laden Sie pdf Betriebshandbuch für Skalen Anyload EC100 herunter. Anyload EC100 12 Seiten. Counting scale
Auch für Anyload EC100: Betriebshandbuch (6 seiten)
[CE]
[QTY/SET]
MEMORY [M+]
MEMORY
CANCEL [MC]
[TOTAL]
[SAMPLE/U
NIT] (lb/Kg)
4.2 Indicator Lamps
LAMP
ZERO
TARE
LACK of SAMPLE
5.
Operation
5.1 Tare
5.1.1. Reduce tare weight
Place the empty container on the platter. Press [TARE] key, the
tare indicator turns on and the WEIGHT display shows Zero. Removing
the container from the platter a f t e r taring, the WEIGHT display
will show a minus sign.
5.1.2. Clearing the previous tare value:
Remove weights from the platter then press [TARE] key. The Tare
indicator turns off and WEIGHT display will return to Zero.
5.2 Sample Settings
There are two sample setting methods:
4 |
ANYLOAD EC100 Counting Scale Operations Manual (V1611)
To cancel the numeric setting data or cancelling
the previous unit weight data
For the alternation of changing normal counting and
quantity check operation
To store accumulated counts data into memory, up to
99 counts
To cancel stored data
For the alternation of changing normal counting
and memory data recalling
To select weight unit; Once the unit is selected,
the selected unit indicates the different calibration
and weighing unit.
"ON"
When the gross weight is zero
When tare weight is set
When the sample unit weight is not heavy enough for
accurate counting operation in case of number of sample
setting mode