W- The combined capacity of the bilge system is not designed to withstand bailing of the
boat if the hull is damaged.
3.16 Fuel System
The system comprises of a fuel tank, venting and filling. Watch out for any spillages or
odours in order to ensure the best possible function. An inspection hatch for the tank is fitted
in the middle sofa. Fuel filters are mounted in the anchor box in front of the engines.
3.17 Control
Hydraulic control with capacity for engines up to 1x300 hp. See the manual for care and
maintenance. Oils other than the oil prescribed must not be used. When fitting engines from
1x350 hp to 2x400 hp the boat must be equipped with power assist. This is needed to maintain
stiffness in the steering system at high speeds
3.18 Cooling system
Cooling water is taken in via the rig. Be careful when tilting out the engine too far while it is
running so that the intake is over the surface of the water.
W-The engine has an overflow pipe that can be used to verify that water is being
pumped to cool the engine
3.19 Storage
The storage compartments are ventilated and have rugged hinges made of aluminium. Grease
them if needed.
W-Never keep things in the storage that is located below deck in the stern. The electrical
equipment that is fitted there can get destroyed