Duevi EZY-LAN HW 4A Handbuch für Installateure - Seite 8
Blättern Sie online oder laden Sie pdf Handbuch für Installateure für Sicherheitssystem Duevi EZY-LAN HW 4A herunter. Duevi EZY-LAN HW 4A 13 Seiten. Wireless alarm panel with ethernet + wi-fi + gsm + lte
•
Action Name: is the name with which the
Action is identified in all menus, notifications,
events, etc.
•
Type of Action:
✓ Arming
-
Operation on Sectors: No change [the
sector
keeps
Activate
Deactivate [the sector is disarmed].
✓ Relay control
✓ White light contro
✓ RGB light control
✓ Rolling shutter control
Once the type of output control has been
selected, it is possible to select one or more
outputs to control and the command to use, which
can be selected from the following:
•
Deactivate - Deactivates the relay or turns off
the light
•
Activate - Activates the relay or turns on the
light (with the last stored settings)
•
Switch over - Changes state to relay or light.
If the relay is active (or the light is on) it
deactivates it (or turns off the light) and vice
versa
•
Open
completely
completely
•
Close completely - Completely closes the
shutter
•
Set - Sets all the features available for the
output based on the type of output:
-
Brightness
-
Color temperature (K)
-
Fade
-
RGB color
-
Opening percentage (roller shutter)
12.4 Users (SETUP)
USERS
can
control
competence through:
•
Use of the App with username and password
•
Keyfob
The USERS page contains the list of all created
users.
By default there is only the installer user, the only
user who has access to the control panel setup.
Pressing the icon
Pressing the icon
settings, where you can change the properties
and tools used.
•
User Name: is the name by which the user is
identified in all menus, notifications, events,
etc.
•
User type:
its
previous
[the
sector
is
-
Opens
the
the
sectors
of
(trash can) deletes the User.
(gear) you enter the User
-
-
-
•
Associated sectors: indicates which sectors
state],
the user can control
armed],
•
Allowed scenarios: indicates which scenarios
the user can execute
•
Allowed images: indicates which devices with
video verification the user can see
•
Time limitation: [only for Normal user] enables
the user only within the time slots established
in the selected time program
•
Generate arming notifications: enable/disable
the generation of notifications every time the
user changes the arm status
•
Phone 1/2: telephone numbers to which text
messages / calls can be sent
•
Email: email address to which notifications
should be sent
Tools
•
Username (APP): username for APP login
•
Password (APP): password for APP login
shutter
Keyfob Management
Pressing the icon
wireless keyfob. First press button 5 and then at
the same time also button 6.
Once a keyfob has been added, the association
of the programmable buttons will also appear.
Pressing the icon
keyfob.
The 1-2-3-4 buttons are freely programmable
Button 5 is programmable only for panic alarm /
silent alarm
NOTE: The operations assigned to the
buttons must first be defined in the
their
ACTIONS or SCENARIOS
Button 6 is not programmable, it can only
request system status and then displays:
TOTALLY ARMED
DISARMED
PARTIALLY ARMED
12.5 Notifications (SETUP)
The NOTIFICATIONS page allows you to enable
the various notifications that the control panel
sends to users.
The notifications available are text messages,
voice call, email, push notification.
It is possible to view notifications by Category or
by User.
Administrator
[user
privileges, can enable installer, can modify
notifications, etc],
Normal [user with reduced privileges],
Police [user limited to the telephone
number to call in case of alarm]
(plus) you can add a new
(trash can) deletes the
with
extended
Led 1/2/3/4 steady ON
Led 1/2/3/4 flashing
Led 1/2 steady ON
Led 3/4 OFF