1-1. General

This manual provides instructions for the installation,
operation and maintenance of the Duff-Norton 6415
Series DC actuator. It includes proper procedures for
the disassembly, cleaning, inspection, rebuilding and
assembly of the actuator. To ensure efficient, long,
satisfactory use of this unit, these instructions should be
followed closely.

1-2. Industrial Use Only

The actuators described and illustrated in this manual
are intended for industrial use only and should not be
used to lift, support or otherwise transport people, unless
you have a written statement from Duff-Norton Company
which authorizes this actuator unit, as used in your
application, as suitable for moving people.

1-3. Factory Preparation

Each actuator is carefully assembled and tested at the
factory to ensure that the motor and the mechanical
components will function properly and that the actuator
will lift its rated load.
The brake is preset at the factory and no further
adjustment is required. With proper maintenance, this
brake prevents the actuator from self-lowering.
The actuator is pre-lubricated at the factory and thus
requires minimum maintenance.
Limit switches are checked at the factory for proper
functioning.
External wires are provided for customer hookup. Wires
are color coded as to direction of travel of the actuator
(see wiring diagram, Figure 6.2).
1-4.

Warranty and Warranty Repair

Subject to the conditions stated herein, Duff-Norton
will repair or replace, without charge, any parts proven
to Duff-Norton's satisfaction to have been defective
in material and workmanship. Claims must be made
within one year after date of shipment. Duff-Norton will
not repair or replace any parts that become inoperative
because of improper maintenance, eccentric loading,
overloading, chemical or abrasive action, excessive heat,
or other abuse.
Equipment and accessories not of Duff-Norton's
manufacture are warranted only to the extent that they
are warranted by their manufacturer, and only if the
claimed defect arose during normal use, applications
and service. Equipment which has been altered or
Section 1

Introduction

modified by anyone without Duff-Norton's authorization
is not warranted by Duff-Norton. EXCEPT AS STATED
HEREIN, DUFF-NORTON MAKES NO OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
WARRANTIES OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE.
If you have any questions concerning warranty repair,
please contact the Duff-Norton Company.
Authorization for return must be received from the
Duff-Norton Company before returning any equipment for
inspection or warranty repair.

1-5. Specifications

Table 1-1. 6415 Series DC Actuator
Applied
Speed
Load (lbs)
(in.min)
500
1000
1500
# Total inches of travel (up and down) per hour with
equally timed intervals between cycles.
* Total inches of travel (up and down).
Table 1-2. 6415 Series DC Super Pac
Duty figures are based on 75˚F (24˚C) ambient
temperature. All ratings are nominal and are based on
actuator being broken-in for approximately 2500 inches
of travel
3
Specifications
Amps
Duty Cycle #
(in/hour)
36
15
1500
31
21
750
26
27
280
Actuator Duty Cycle
NOTE
Continuous
Duty* (in)
1300
300
See Table 1-2