T
RUCK REQUIREMENTS
WARNING: Rated capacity of the truck/
attachment combination is a responsibility of the
original truck manufacturer and may be less
than that shown on the attachment nameplate.
Consult the truck nameplate.
Truck Relief Setting
2300 psi (160 bar) Recommended
2600 psi (180 bar) Maximum
Truck Flow Volume
20E, 30E, 33E,
40E, 45E
Cascade E-Series Clamps are compatible with SAE 10W
petroleum base hydraulic fluid meeting Mil. Spec. MIL-0-5606 or
MIL-0-2104B. Use of synthetic or aqueous base hydraulic fluid
is not recommended. If fire resistant hydraulic fluid is required,
special seals must be used. Contact Cascade.
Flow less than recommended will result in reduced system
performance.
Flow greater than maximum can result in excessive heating,
reduced system performance and reduced hydraulic system life.
Carriage Mount Dimension (A)
A
Class II
Class III 18.68 in. (474.5 mm)
GA0028.ill
Auxiliary Valve Functions
Check for compliance with ITA (ISO) standards:
GA0082.ill
212115 Rev. 0
Min.
Recommended
5 GPM
7.5 GPM
(19 L/min.)
(28 L/min.)
Minimum
14.96 in. (380.0 mm)
15.00 in. (381.0 mm)
18.74 in. (476.0 mm)
Tilt
forward
Sideshift
Hoist down
Left
Hoist up
Sideshift
Right
Tilt
back
Max.
10 GPM
(38 L/min.)
ITA (ISO)
Maximum
Release
Clamp
Carriage
Clean carriage bars and inspect for
damaged notches
GA0080.ill
1