Dandy Locks Janus TN Benutzerhandbuch

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Durch Schlösser Dandy Locks Janus TN herunter. Dandy Locks Janus TN 2 Seiten.

JANUS TN USER MANUAL
ADMINISTRATOR CODE SET UP
1. Press the "registration" button for 5 seconds and
wait for the beeping sound and the red LED will turn
on.
2. Enter the administrator code and press 【#】 . Re-enter
the code to confirm and press【#】.
3. When you hear a chime, the setup is complete.
The
preset
up
administrator
【12345678】. We strongly suggest changing
it after installation.
All codes should be between 4~12 digits.
The system has a built in scrambler function.
Meaning before manually turning off the
function, two random digits will be on before
continuing operation. Press these two digits in
any order and the rest of numbers will appear.
Maximum number of users is 63 sets. (This
includes cards, phones, and security codes)
REGISTERING CARD KEYS& PHONES
1.
Enter「Administration Code」and press【*】 。
2.
Press【1】to register a new user.
3.
Press【1】again to register CARD or PHONE.
4.
Place CARDS or PHONE in front of the lock.
5.
When you hear a chime, the setup is complete.
6.
Repeat step 4~5 to register multiple cards or phones.
7.
Press【*】twice to exit.
DELETING CARD KEYS & PHONE KEYS
1.
Enter「Administration Code」and press【*】.
2.
Press【2】to delete existing keys.
3.
Press【1】to delete CARD or PHONE.
4.
Place CARDS or PHONE in front of the lock.
5.
When you hear a beep, cancelation is complete.
6.
Repeat step 4~5 to delete multiple cards or phones.
7.
Press【*】twice to exit.
DELETING ALL USER KEYS
1.
Enter「Administration Code」and press【*】
2.
Press【3】to delete all user keys.
3.
Press【1】to confirm delete all user keys.
52-EC300-04 BAP060 第一版
BASIC SETTING
MINISTRATOR PHONE SET UP
AD
1.
Download Key Butler in Google play or scan QR Code
on the second page
2.
Download and turn on app "Key Butler",press
「ADD LOCK」 。
3.
Enter DIN "JANUSTN" and name your lock.
4.
After pressing 【 >】 , there will be instructions for setting
up for setting up your phone. Please do NOT exit this
code
is
page during setup
5.
Holding the button under the battery pack for 5 seconds,
and release the button after hearing the beeping and
when the red LED is turned on.
6.
Place your phone in front of the lock (contacting the
back of the phone with key reader area on the lock) and
you will hear a chime when the set up is complete.
7.
See Key Butler manual for more instruction.
 Place NFC phone or cards in front of sensor area.
Keep the distance within 2cm.
REGISTERING SECURITY CODES
1.
Enter「Administration Code」and press【*】.
2.
Press【1】to register a new user.
3.
Press【2】to register security code.
4.
Enter new「Security Code」and press【#】.
5.
Enter again new「Security Code」and press【#】.
6.
When you hear a chime, the setup is complete.
7.
Repeat step 2~6 to register multiple security codes.
8.
Press【*】 to exit.
DELETING SECURITY CODES
1.
Enter「Administration Code」and press【*】.
2.
Press【2】to delete existing keys.
3.
Press【2】to delete existing codes.
4.
Enter existing code and press【#】.
5.
When you hear a beep, cancelation is complete.
6.
Repeat step 2~5 to delete multiple codes.
7.
Press【*】 to exit.
4.
You will hear a beep when cancelation is complete.
5.
Deleting all users will also delete administrator
phone.
6.
Press【*】 to exit.
BASIC OPERATION
1.
Place valid cards or phones within 2 cm in front of
sensing area of the keypad to
unlock.
2.
To wake up the keypad, use
the palm touch, and touch
two digits that lights up in
any order (only required if
scrambler function is on).
Enter valid security code then
press【#】to unlock.
※ Scambler and anti-peeking functions are on as
pre-setup.
3.
When the lock is successfully unlocked, you will hear a
beep and blue LED will be on. Press outside lever to
open the door within 5 seconds.
4.
The lock will be automatically locked after 5 seconds.
5.
After 3 invalid password inputs, the alarm will go off and
the keypad will be locked for 3 minutes.
PRODUCT SPECS
Lock-case:Standard ANSI US mortise lock-case
Door thickness:40 ~ 60mm
Backset :2-3/4" (70mm)
Environment:0°c~ 60°c
Operating voltage:6VDC(LR6-AA*4,2500mAh)
Unlock Method:NFC Phone、RFID card、Security
Code、Mechanical Keys
Card key spec.:ISO 14443 A type RFID(Mifare)
Operation APP:Key Butler (Android)
Low battery warning:Low battery warning appears 10
short "bi" and flashing red LED after unlocking.
Replace all 4 batteries within 7 days when the low
battery warning appears.
CAUTION
You can use your ISO 14443A type RFID card (e.g.
credit card or pass card) as your card key. Sensing
distance may differ due to different types of cards.
NFC sensor locations on phones may differ on different
models of phones. Please consult your dealer for NFC
sensor location details. For best performance, please
keep the NFC sensor as close to the keypad sensor as
possible.
This product is uses low power cordless configuration.
Sensitivity of the card may be affected if the card keys
is located inside a wallet .
When the batteries are low on power or completely
discharged, you can easily supply emergency power to
the lock with the 9V battery.
WARRANTY
Use fresh alkaline batteries for best result. Other types
of batteries (e,g, zinc-carbon battery) may cause errors
or faulty operation. Battery life may vary due to
temperature, moisture, frequency of use, and the quality
of the batteries.
1.5V AA size battery can be identified with『Size
AA』 、 『Alkaline』or『LR6』on the battery.
We suggest changing the batteries immediately after
expiration. Fresh batteries will assure maximum
performance and flawless operation. Do not use
expired battery. All warranty will be void under use of
expired batteries
Battery fluid leakage may cause damage to the product
or even explosion of the batteries. Please always use
premium alkaline batteries. Also, always change all
batteries at the same time. Never mix fresh batteries
with used batteries.
Disassembly, re-work or tampering of the system will
void the warranty.
The products warranty does not cover defects or
damages arising from the door defects, improper
installation, lack of or improper maintenance, improper
storage, shipping and handling, ordinary wear and tear,
misuse, abuse, accident, unauthorized service or use
with unauthorized service parts.