Dukane iQ LS-E Anwendungshinweis - Seite 9

Blättern Sie online oder laden Sie pdf Anwendungshinweis für Stromversorgung Dukane iQ LS-E herunter. Dukane iQ LS-E 16 Seiten. Ultrasonic probe system, automation interface guidelines

DUKANE
Intelligent Assembly Solutions
iQ System Outputs
Notes:
1. All System Outputs share the same Isolated Common (J3-24). It is critical that the isolated common is connected
to the positive supply or ground.
2. J3-1 can be used in place of the 24Vdc supply. If so, J3-24 must be connected to J3-1 and 0Vdc to J3-3.
AN502 (REV 07)
Page 9 of 16
Connecting a PLC Sinking Input Card
+24Vdc Supply
(+30Vdc max)
Isolated Common J3-24
iQ Digital Outputs
PLC Digital Input
Sourcing Current
Sinking Current
APPLICATION NOTE
PLC Input Card
0Vdc Return
AN502
© Dukane 2016. All Rights Reserved.