Installation Instructions

Installing the Terminal Cover

After installing the cable clamp kit, replace the terminal cover and lower cover panel using the following steps. Refer to
Illustration 1.1.
1.
Tilt the front of the terminal cover downward until
the fastener points rest on the slotted drive brackets.
2.
Make sure that the side panels of the terminal cover
are on the outside track guide.
3.
Push the terminal cover until it is positioned against
the slotted drive bracket.
4.
Tilt the front of the terminal cover upward until the
fastener hole in the drive aligns with the keyhole
opening in the terminal cover.
5.
Secure the terminal cover with 2 screws (T20). Torque
to 2.3 Nm (20 in-lb).
6.
Replace the lower cover panel and fasten with 4
screws (T25). Torque to 2.3 Nm (20 in-lb).