Abus IPCB42500 Benutzerhandbuch Hardware - Seite 16
Blättern Sie online oder laden Sie pdf Benutzerhandbuch Hardware für Sicherheitskamera Abus IPCB42500 herunter. Abus IPCB42500 18 Seiten.
3. Connections and functions
3.1 Power supply
ATTENTION!
Before you begin the installation, make sure that the supply voltage and the nominal
voltage of the camera match.
3.2 Call factory default settings (Reset)
1. Please disconnect the camera form power connection.
2. Press the "Reset" button on the camera and keep it pressed.
3. Now connect the power supply to the camera (2-pin power supply or Power over
Ethernet), and hold the "Reset" button pressed for another 30 seconds.
3.3 Switching input/output
The maximum load values must be observed, otherwise, the camera may be
irreparably damaged.
Switching input
Switching output „O"
Description
Connection information
„I"
Bridge between „Alarm In" and „GND"
„GND"
5 VDC ~12 V DC, max. 30 mA, please note the connection
polarity
„GND"
12 VDC, round plug, 5,5 x 2,1 mm
16