DUOMATIC 50 B Gebrauchsanweisung

Blättern Sie online oder laden Sie pdf Gebrauchsanweisung für Zeitschaltuhr DUOMATIC 50 B herunter. DUOMATIC 50 B 2 Seiten.

Operating instruction
The DUOMATIC 50 B timer is compatible
with all standard switch programmes with
50mm x 50mm cutouts (in accordance with
DIN 49075).
Reset Mode
ATTENTION!
This appliance is not intended for use by
person (including children) with reduced
physical, sensory or mental capabilities, or
lack of experience and knowledge, unless
they
have
been
given
instruction concerning use of the appliance
by a person responsible for their safety.
Children should be supervised to ensure
that they do not play with the appliance.
Wiring diagram
Motor
Terminal
Technical appliances data
Nom. operating voltage:
Switching voltage:
Switching contact load:
Temperature range:
Travel time:
Switching delay:
Accuracy:
Reserve power:
Degree of protection:
Safety class:
Conformity:
ATTENTION! Work on the 230V supply may only be carried out by a certified electrician!
DOWN button < 1 sec. Inching mode; or STOP when motor running
DOWN button > 1 sec. DOWN command 2 min.
UP button < 1 sec.
UP button > 1 sec.
Mode button > 2 sec.
Mode button < 2 sec.
Reset button
Press the Mode button
> 2 sec.
Set the time with the
UP or DOWN buttons
Confirm with the Mode
button
Set the UP time with
the UP or DOWN
buttons
Confirm with the Mode
button
supervision
or
Set the DOWN time
with the UP or DOWN
buttons
Confirm with the Mode
button
If the RESET button is pressed all values return to the factory settings:
Daily programme:
Time:
Function mode:
Pressing the Mode button switches through all possible function modes
successively. You can select from 3 modes:
man
auto
In the automatic mode the shutters are raised or lowered automatically at
the programmed times.
230V / 50 Hz
250V AC
3A (cos phi=1)
Touch the direction buttons (about 1 sec.) to slant the blind slats. The
0°C to +45°C
system remains in the Automatic mode.
2 min.
min. 0,5 sec.
< 5 sec./day
≥ 16 hrs.
If the random generator is activated the programmed UP and DOWN times
IP 40
are moved back randomly by 1 - 31 minutes.
II
CE
Operating the timer
Inching mode; or STOP when motor running
UP command 2 min.
Activating the programming mode
Changing the operating mode (manual mode;
automatic; random automatic)
Initialising the appliance (new start); appliance is
reset to the factory settings
Programming the timer
Time blinks. After new initialising and RESET the
factory setting blinks (=> 12:00h).
As soon as the UP or DOWN button is pressed
the display stops blinking. If the UP or DOWN
button is held the time display accelerates up to
half-hour steps.
Current UP time is displayed. UP arrow blinks.
After new initialising: factory setting UP time
(=> 07:00h).
If the UP or DOWN button is held the time display
accelerates up to half-hour steps. UP arrow
blinks.
Current DOWN time is displayed. DOWN arrow
blinks. After new initialising: factory setting DOWN
time (=> 21:00h)
If the UP or DOWN button is held the time display
accelerates up to half-hour steps. DOWN arrow
blinks.
Exit from programming mode; time and selected
mode are displayed.
Factory settings
UP 07:00h, DOWN 21:00h
12:00h
man
Possible function modes
Manual control
Automatic (daily programme)
Automatic (daily programme) + random generator
Inching mode
Random generator
DUOMATIC 50 B