pecifications
S
Power:
ohms from 30Hz to 15KHz at no more than 1.5% total harmonic
distortion or intermodulation distortion (can be re-connected in-
ternally for 8 or 16 ohm loads).
Sensitivity: .5 V rms to rated power
Small Signal Distortion: less than .2% at mid-band
Frequency Response: 20Hz to 20 kHz +0/-.25 dB
Hum and Noise: 102 dB below rated power output
Phase: phase correct
Input Impedance: 100 kOhms
Mechanical
Dimensions: 16.125"D x 19"W x 6.375"H
Net Weight: 54 lb net
Fuses
The LP70S power transformer is protected by a fuse on the ac
power line (F5, located in a compartment in the ac line-cord recep-
tacle mounted on the back of the amplifier), and by four separate
internal fuses on t h e secondary circuits of the transformer (F1 –
F4) located on the bottom of the pc board. A failure of any of these
fuses is a symptom of a more serious problem, and a competent
service technician should be consulted. In no event should fuses
be replaced with a value or type different than that originally sup-
plied. The correct fuse values and types are:
70 watts per channel RMS both channels driven into 4
F5:
5x20mm 5 amp T-type if configured for 100 or 120V:
5x20mm 3 amp T-type if configured for 220 or 240V.
F4: 3AG type 4 amp, slow blow
F1, F2, and F3: ¼ amp, slow blow