Blättern Sie online oder laden Sie pdf Handbuch für Toröffner Casit EQ2006 herunter. Casit EQ2006 14 Seiten. Control box gate's opening-2 motors singlephase 230vac
Input N.C. PHOTOCELL 1.
17-18
Photocell trained in both the senses of march. The conditions of operation depends on S2 – dip 5.
M8
Input N.C. PHOTOCELL 2. Photocell activates only in closing (it arrests and it reopens).
17-19
The conditions of operation with the gate is closed depends on S2 - dip 6.
Input N.C. LIMIT SWITCH OPENING 1.
20-22
Limit switch of opening of the motor 1.
Input N.C. LIMIT SWITCH CLOSING 1.
21-22
Limit switch of closing of the motor 1.
M9
Input N.C. LIMIT SWITCH OPENING 2.
22-23
Limit switch of opening of the motor 2.
Input N.C. LIMIT SWITCH CLOSING 2.
22-24
Limit switch of closing of the motor 2.
Input N.C. STOP.
25-28
It arrests the movement of the gate.
Input N.O. START (S1 - dip 3 ON).
M10
26-28
Input N.O. OPEN (S1 - dip 3 OFF).
Input N.O. PEDESTRIAN (S1 - dip 3 ON).
27-28
Input N.O. CLOSING
Output warning light functions 24Vac.
29-30
M13
It is out to when gate is closed , it has turned on when gate is open.
30-31
Output ELECTROLOCK; 12Vac, max. 1A.
Output 24Vac to use for feeding the transmitting station of the photocells when the function "test photocells" is
32-33
activated.
M11
33-34
Output 24Vac.
Input aerial for radioreceiver RX
35-36
Aerial Cable to 36, eartn to 35.
M12
41
Input external N.A. of RX1, GND 35
Contact N.C. safety.
M14
37-38
The opening of the contact removes the feeding from the spools of the relays disarming the outputs.
M15
39-40
Clean contact of the 2° channel of the radioreceive r on the connection J1 RX.
WARNING : The inputs N.C. not used they must obligatorily be short-circuits toward the commune of the entries
CONNECTIONS J1 RX = graft for the receiver.
2) DIODE LED
L1
Line of feeding; turned on to control panel fed
SAFETY EDGE 1; it switch on to the intervention of the safety edge 1.
L2
The flashing led L2 points out the condition of triac TH1 (pilot motor 1) in damage.
SAFETY EDGE 2; it switch on to the intervention of the safety edge 2.
L3
The flashing led L3 points out the condition of triac TH2 (pilot motor 2) in damage.
L4
PHOTOCELL 1; it switch on to the intervention of the safety edge 1.
L5
PHOTOCELL 2; it switch on to the intervention of the safety edge 2.
L6
OPENING LIMIT SWITCH 1; it switch on to the intervention of the limit switch open of the motor 1.
L7
CLOSING LIMIT SWITCH 1; it switch on to the intervention of the limit switch close of the motor 1;
L8
OPENING LIMIT SWITCH 2; it switch on to the intervention of the limit switch open of the motor 2.
L9
CLOSING LIMIT SWITCH 2; it switch on to the intervention of the limit switch close of the motor 2.
L10
STOP; it switch on during the stop command.
L11
RX1; it switch on during the impulse of the remote control.
L12
START; it switch on during the start command.
L13
PEDESTRIAN; it switch on during the pedestrian command.
REV 1; it switch on red to the intervention of the reverse on the motor 1 during the work and it visualizes the last
L14
seconds of the stroke turning on itself green.
REV 2; it switch on red to the intervention of the reverse on the motor 2 during the work and it visualizes the last
L15
seconds of the stroke turning on itself green.
SET; it marks the regular operation of the microprocessor of the control panel with some green continuous
L16
lightning during the work.
3) DEVICES OF PLANNING
The pushes button PS1s (START), PS2 (Pedestrian), PS3 and the leds L14, L15, L16 are used for the formulation of the parameters
in the planning menu (see chapter 6).
4) CONTROLS POWER
P1
It set the power of the motor 1.
It set the sensibility to the obstacle while motor 1 is
P2
working.
It set the sensibility to the obstacle while motor 1 is
P3
slowing down.
Page 3 of 14
If the motor is complete with limitswitches, you have to
connect them to the controlboard but not to the motor phases.
(S1 - dip 3 OFF).
P4
P5
P6
EQ2006 R.1.5
It set the power of the motor 2.
It set the sensibility to the obstacle while motor 2 is
working.
It set the sensibility to the obstacle while motor 2 is
slowing down.