audiophony AMP240 Benutzerhandbuch - Seite 6
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Verstärken audiophony AMP240 herunter. audiophony AMP240 12 Seiten.
English
1
Indicator LEDs
These LEDs indicate the status of your device:
- SIGNAL: Indicates an incoming signal.
- -20 dB: Indicates the signal is in the best range
possible, for an optimal sound quality.
- CLIP: Indicates the signal sound level is too high.
- PROTECT: Indicate the amplifier is in protection mode
due to overheating or short-circuits.
Notes :
- The PROTECT LED should always light up upon
activation of your device.
- If the PROTECT LED remains lit, please turn your
amplifier off, wait for it to cool down and check the
wiring.
- If this LED remains lit and previous instructions have
been observed, please contact a qualified technician.
2
Power switch
Allows you to turn ON/OFF your device. The POWER
LED will lit when your device is activated.
3
24V DC Connector
The AMP120/240 amplifiers might be set up in public
places as public adress devices. In order to prevent
them from being deactivated upon power failure, they
feature a 24V emergency power input.
4
Power input with fuse
Connect here the supplied IEC cord and connect it to an
electrical outlet after making sure the delivered voltage
is compatible with your device.
Fuses
AMP120
T3.15AL / 250V
AMP240
T6.3AL / 250V
5
Output terminals
Connect here your speakers or recessed speakers.
These terminals can be used in many ways, depending
on your installation.
Please refer to next chapter for more details about the
different types of installations.
6
INPUT ADJUST control knob
Allows you to adjust the incoming signal from -12dB to
0dB.
Page 6
AMP120/240 - 120/240W Public Address Amplifier with 4 Ohms/70/100V outputs
7
HPF Switch
This switch allows you to activate or deactivate the high-
pass filter.
Activate this filter when noticing humming or buzzing
noises.
8
INPUT and LINK sockets
INPUT : Connect here a line-level source.
LINK : Allows you to send the signal to another device.
9
GROUND Switch
Allows you to connect the housing to the ground.
When a "snoring" noise close to 50Hz appears, position