[Maintenance and repair]
·
Attention
Regular level 3 maintenance of light
Check the tension of screw firmness that operating within the light (color dish's fixed
screw)
Clean up the dust and debris and keep the light clean.
Clean the glass lens within the light (reflectors, color piece, corrugated mirror etc.)
The excessive dust, smoke and particles can be eroding appearance of light even damage
equipment for overheating
Off the power before detach shell of light
Please off power before maintaining.
·
Cleaning
Disconnect the power, cool light completely. Remove the lamp cover.
Use a vacuum cleaner or air compressor produced gas to remove the dust of surface of
light.
Optical lens need clean every week, or it will reduce brightness.
Cooling fans need clean monthly. Ensure the vent fan smooth to ensure the cooling effect
of the bulb.
Check gas nets, such as clean up jam filter, change filter gas nets when needed.
The clean of gobo must use soft brush. Light internal clean at least six months, can use
the vacuum cleaner or air compressor produced gas removal dust.
Color pieces, gobo pieces and the optical mirror need to clean monthly.
Clean optical element be careful, It is easy to stroke and damage of optical components
surface, don't using liquor, it may damage the coating surface of optical lens.
In order to ensure the normal function of gobo wheel and focus, we suggest add
lubricating oil in the bearings every six months. Remember: oil cannot too much,
especially the gobo wheel, or it will cause other problems for the oil would flow when gobo
wheel or gobo rotation.
Clean PCB board every three months (too much dust and dirt can lead to PCB work
un-normal); Please with soft brush or air compressor produced gas to remove dust (air
pressure can not be too strong).
Lamps and lanterns without any useful things except bulb insurance tube,
Please installation and replacement bulbs according to the instructions of the manual.
Replace insurance pipe
If you want to change insurance tube, please replace with original (including current
voltage, etc.)
Please draw power plug before replacement insurance pipe, avoiding dangerous!
Danger! ! !
3