Audiophony PA BM-Control Benutzerhandbuch - Seite 13
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Messgeräte Audiophony PA BM-Control herunter. Audiophony PA BM-Control 16 Seiten. Magnetic field strenght meter
AUDIOPHONY PUBLIC ADDRESS
5.3
Notes and requirements of Standard 60118-4
The standard states that the signal level in the loop area should not vary by more than ± 3dB.
Once confirmed, the signal level from the normal building program should peak at 0 dB as
referenced at 400mA/m. This confirms that there is adequate loop current to produce both
maximum and average signal levels (average is de-12dB or 100ma/m) for hearing instruments
equipped with the T position.
6 - Specifications
Scale calibration
Operating mode -20dB
Operating mode 0dB
Type de measurement
Frequency response
Filter
30Hz ~ 500Hz
500Hz ~ 2500Hz
2500 ~ 10kHz
Outputs
Display
Headphone
Power supply
Batteries
Indicator lights
Service life
Dimensions
Dimensions (L x H x P)
Weight
-20dB = 0,043A/m
0dB = 0,4A/m
True RMS 125ms
A/Flat
-3dB ~ -4dB
+/-0,25dB
+/3dB
Color-coded LED dot display
3,5mm stereo Jack
2 x LR6 - AA
LED
100h
83 x 126 x 35 mm
Approx 300g
English
Page 13