In operation, the VCMute features a two-color LED that indicates the status of both your stereo system and the room you are
in. When someone turns on the stereo, all volume controls stay muted and light up their red LED's, indicating that the stereo
is on. A momentary push of the button turns on that location. When you "un-mute" the room to listen, the LED will turn to
green. Holding the button in for 3 seconds will turn on all locations (party mode). To reset all locations to mute, power
down the amplifier or press the "All Zones Stand By" button on the VCPage-Base.
When the control button on the VCPage side of the unit is pressed and held, an all zone page will occur. There will be a 3
second delay before someone can respond. A green LED will illuminate on the VCPage indicating a real-time page can be
made. The LED on the VCMute side of the unit will glow red indicating the room is temporarily muted and able to receive a
page. After the VCPage control button is released, all rooms will return to their previous state (listening to music---green
LED or muted---red LED on the VCMute). The level of the page is controlled at the VCPage-Base. "Page Levels-Zones" is
the master gain for the VCPage plate volume---page volume is independent from the audio volume control on each VC plate.
Privacy Buttons:
Voice pages, doorbell chimes and the VCMute's "all on" features can be over ridden in individual rooms from the VCPage-
Base unit. Operating the privacy buttons on the front of the VCPage-Base, a single zone can be temporarily taken off line
retaining only "local commands" (i.e. local mute, local un-mute). Infrared control of source equipment will be retained even
when the zone is selected as private. No pages will be received in the room, the doorbell interface will not chime into the
room, and the room will not be turned on by a global command from another VCMute until re-selected into the system at the
VCPage-Base.
All Zones Stand By Button:
All VCMute zones can be instantly re-muted by pressing the "All Zones Stand By" button located on the far left of the
VCPage-Base's front panel. Push and hold this button for 3-5 seconds to mute all zones.
NOTE: ALL zones in the system will revert to the mute state with this function---even zones selected as "private"
on the VCPage-Base.
IR Repeating and IR Emitter Output:
The Audiplex X-40 Infrared Repeating Systems can also be tied into the VCPage-Base. VCMutes with X-40 IRTargets built
onboard can be home run to the Base unit and the three (3) IR emitter output jacks, located on the rear of the VCPage-Base,
can be used to control source equipment. (IRBug and IRFlood emitters are sold separately).
The X-40 IRTarget built onboard share power and ground with the VCPage plate (12P and PGD); The X-40 IRTarget does,
however, have its own signal line, designated as IR on the VCPage-Base which will need to be home run separately to the
VCPage-Base. Use the eighth conductor of the CAT-5 wire.
IRTargets other than VCMutes built with X-40 onboard should be home run to the 12P (12v DC), PGD (ground) and IR
(signal) terminals on the VCPage-Base for proper operation.