Engineers Mode allows you to adjust the Volume In and Out levels, Ducking
levels and Hearing Loop levels to better suit your environment and achieve
the best possible performance.
Before entering engineers mode, cycle the power. To do this either:
Switch the power off at the mains socket and back on again
Remove the power connector and re-insert it
To enter engineers mode, simultaneously press and release the following
buttons within 20 seconds of cycling the power:
Settings button
Volume In increase button
Volume Out increase button
Number 1 LED on the Volume In will flash green to indicate that you are in

Engineers Mode.

The on/off and settings buttons in engineers mode operate as follows:
Move to the next setup area
The amplifier will automatically exit engineers mode if no buttons are
pressed for 2 minutes.
There are 3 editable setup areas in engineers mode. You will always enter
setup area 1 first. The green Volume In LED bar will flash to indicate which
setup area you are in.
Setup Area 1 allows you to adjust the Volume In and Volume Out levels to
further optimise the system for the environment in which it is installed.
Increase maximum
staff volume level
Decrease maximum
staff volume level
6
Engineers Mode
Maximum Volume Adjustment (LED 1 flashes)
Save and exit engineers mode
Setup Area 1:
Increase maximum
customer volume level
Decrease maximum
customer volume level